INSTALLATION GUIDE
Station is a complete pool controller which doses pool-
chemicals in order to maintain the pool water in perfect
conditions. The base product controls the temperature,
filtration periods, pool lighting and 4 additional
relays. The base product is upgraded by adding the
measurement and control of up to 4 water parameters.
The management of the additional parameters can also
be upgraded post-sales via “upgrade kits”.
1
DESCRIPTION
Electronic box
2
A
B
1
9
10
15
16
17
4
5
6
88
C
A
B
C
Filtration pump timer *
Silex / glass / diatom filter
Recirculation pump
1
4
5
Electronic box
pH probe
(optional - for models with pH control)
redoX probe
(optional - for models with redoX control)
Conductivity probe
(optional - for models with conductivity control)
6
Acid dosing pump
(optional - for models with pH control)
Acid injector
(optional - for models with pH control)
Hydrochloric acid container
(optional, for models with pH control,
not supplied with unit)
8
9
10
15
16
17
Other pool equipment
Module RF or RF/WIFI or WIFI
Free chlorine control
SYSTEM INSTALLATION
PORTABLE
COLOR
DISPLAY
(TFT)
WORLDWIDE
REMOTE
CONTROL
WIFI and
MODBUS
FILTRATION
AND LIGHT
CONTROLS
UP TO
4
PARAMETERS
UPGRADE
POSSIBLE
station
3
4
Main connection 220 V
ON/OFF switch
Fuse for device and
cell 3.15 A
Fuse relays 3.15 A
1
2
1
2
110-230 V
* An “Installer Menu” does exist for advanced functions. If you are an authorized installer, please ask your provider for the installers/service manual.
Connection
WIFI / RS module
Device control SLAVE
Digital inputs /
outputs
Connection display
Electrical connections of the electronic box
Chlorine probe
detector (rotameter)
Cover
FL1
Conductivity probe
Temperature probe
pHredoX
Free
Chlorine
DRY CONTACT110-230 V max. 3.15 A
* Filtration control by external timer
Filtration mode:
“Manual/ON”
110-230 V
* Filtration control by internal timer
Filtration mode:
See section 3.2
NEW
MODEL
2015
FAN
LESS
!
pH
pH Control
AUX 1
Base (pump)*
AUX 2
redoX / free chlorine
ppm´s (pump)*
AUX 4
Heating control*
AUX 3LIGHT
Lighting control
FILTER PUMP
Filtration control
14
12
11
A1 A2
LN
110-230 VRelay FILTER PUMP
Question and Answer IconNeed help?

Do you have a question about the sugar-valley STATION and is the answer not in the manual?

sugar-valley STATION Specifications

General IconGeneral
Brandsugar-valley
ModelSTATION
CategoryLighting Equipment
LanguageEnglish

Summary

Description of the Station Pool Controller

Electronic Box Electrical Connections

Details the wiring and connections for the electronic control unit, including probes and power inputs.

System Installation Guide

pH Probe Installation

Details the installation and function of the optional pH probe for water quality control.

Redox Probe Installation

Details the installation and function of the optional redox probe for water quality control.

Conductivity Probe Installation

Details the installation and function of the optional conductivity probe for water quality control.

Acid Dosing Pump Installation

Details the installation and function of the optional acid dosing pump for pH control.

RF/WIFI Module Installation

Details the installation of RF or WIFI modules for system connectivity.

System Functioning and Operation

pH Control Functionality

Explains the metering and control of water pH for pool conditions.

Redox Control Functionality

Explains the metering and control of redox for free chlorine assessment.

Measures and Probe Calibration

Guide for adjusting setpoints and calibrating measurement probes.

pH Probe Calibration Procedure

Recommended monthly calibration for the pH probe to ensure accuracy.

pH Probe Buffer Calibration

Step-by-step guide for calibrating the pH probe using buffer solutions.

Redox Probe Calibration Procedure

Recommended calibration every 2 months for the redox probe.

Redox Probe Buffer Calibration

Guide to calibrating the redox probe using a 465 mV buffer solution.

Filtration Modes and Operation

Filtration Mode Options

Details the different filtration modes available: Manual, Automatic, Smart, Heating, Intelligent.

Pool Lighting Control

Lighting System Overview

Controls lighting for the pool, with manual and automatic modes.

Auxiliary Relay Control Functions

Auxiliary Relay System Overview

Controls up to 4 extra auxiliary relays for various pool equipment.

System Settings and Configuration

Redox Control System Configuration

Optimizing Redox Levels

Steps to determine and set the ideal redox level for pool sterilization.

Pool System Maintenance

Initial System Maintenance

Specific care required during the first 10-15 days of system operation.

General Maintenance Procedures

Routine checks and maintenance for dosing pumps, probes, and general system care.

Troubleshooting Guide

Troubleshooting a Blank Display

Steps to resolve issues with a blank or non-functional display screen.

Troubleshooting Alarm AL3 and Pump Stoppage

Resolving alarms and issues with the pH dosing pump being stopped.

Related product manuals