SRC Service Manual
Revision 02
Aug 2007
7.2 User Parameter List
Parameter Description Units Min Max Default
A1 Temperature Unit of Measure - oC oF oF
A2 Dryer Working Hours hrs 0 999 0
A3 Dryer Working Hours x 1000 hr x 103 0 999 0
A4 Compressor Working Hours hrs 0 999 0
A5 Compressor Working Hours x 1000 hr x 103 0 999 0
A6 High Dewpoint Warning Setting oC 0 70 15
B1 ID Number in Modbus Network - 1 200 1
B2 Serial Communication Speed baud 1200 19200 9600
B3 Reset Service Required Warning* - 0 (no) 1 (yes) 0 (no)
B8 Service Required Warning Interval* hrs x 103 1 999 6
D1 Drain Duration (Time open) sec 1 60 5
D2 Drain Interval (Time closed) sec 1 900 120
D3 Drain Operation Mode - CAP Con TIM
* Parameters B3 & B8 are passcode protected and cannot be changed or reset without the proper
code. Refer to Section 10.3 for further information.
Parameter D3 changes the drain operating mode. Refer to Section 9 for further information.
Page 30 of 56