SRC Service Manual 
Revision 02 
Aug 2007 
 
 
4. Control System 
 
The SRC-150 to 200 feature a base analog controller, while the SRC-250 to 1000 are fitted with a 
microprocessor.  
 
4.1  Power Supply 
 
The following power supplies are offered:  
•  115V/1ph/60Hz +/-10% on SRC-125 & 150  
•  230V/1ph/60Hz +/-10% on SRC-125 through 250  
•  230V/3ph/60Hz +/-10% on SRC-250  
•  460V/3ph/60Hz +/-10% on SRC-250 through 1000 
•  575V/3ph/60Hz +/-10% on SRC-250 through 1000 
 
 
4.2  Controls on the SRC-150 to 200 
 
The SRC-150 to 200 use an analog controller. It features the following functions:  
 
•  Dryer on/off switch.  
•  Dryer on signal (green lamp).  
•  Alarm signal (red lamp).  
•  Dew point indicator 
o  green = dew point ok 
o  red = high dew point 
o  blue = risk of freezing  
•  Automatic restart (after power failure).  
Page 21 of 56