HMP-0567E Rev.7 (1/19)
Instruction Manual
QT Pump / QX Pump
HMP-0567E Rev.7
Read this manual before use.
Sumitomo Precision Products Co., Ltd.
< Industrial Hydraulic Systems >
Tokyo Marketing Section
Sumitomo Corporation Takebashi Bldg 4th floor,
1-2-2 Hitotsubashi, Chiyoda-ku, Tokyo 100-0003, Japan
Phone 81-(0)3-3217-2813 Fax 81-(0)3-3217-2823
Osaka Marketing Section
1-10, Fuso-cho, Amagasaki, Hyogo 660-0891 Japan
Phone 81-(0)6-6489-5946 Fax 81-(0)6-6489-5902
Rev.7 - Nov. 2020
Question and Answer IconNeed help?

Do you have a question about the Sumitomo QT Series and is the answer not in the manual?

Sumitomo QT Series Specifications

General IconGeneral
BrandSumitomo
ModelQT Series
CategoryWater Pump
LanguageEnglish

Summary

Before Using the Pump

Introduction

Provides an overview of the manual's purpose and guidelines for safe and proper pump usage.

Checking the Delivered Product

Instructions for verifying the received product against the order upon delivery.

Safety-Related Labeling

Explains the meaning of safety symbols (Danger, Warning, Caution) used in the manual.

Safety Precautions

Precautions for Handling the Product

Essential safety measures and warnings for handling the pump, including weight and transport safety.

Precautions for Installing/Removing the Product

Safety guidelines for installation and removal, emphasizing qualified personnel and power off procedures.

Precautions for Operation

Safety measures during pump operation, including protective covers and operating conditions.

Precautions for Maintenance

Safety warnings regarding disassembly, reassembly, and alterations without manufacturer consent.

Precautions for Handling and Using the Product

Explanation of Model Number – QT Pump

Details the coding system for QT Single pump model numbers, including size, pressure, and options.

Pump Installation

Guidelines for correct pump installation, including mounting base rigidity and motor rotation check.

Pump and Motor Shafts Alignment

Procedures and tolerances for aligning pump and motor shafts using flexible couplings.

Explanation of Model Number – QX Pump

Details the coding system for QX Single and Double pump model numbers and their specifications.

Suction Filter

Recommendations for selecting and installing suction filters based on environment and operating conditions.

Line Filter/Return Filter

Guidance on when to install line or return filters for system protection, especially in unfavorable environments.

Piping

Instructions for piping installation, including cleaning, diameter selection, and orientation for suction.

Pressure Specifications

Defines rated and maximum pressures for QT and QX pumps and provides specification tables.

Shaft Speed

Specifies the rated shaft speed ranges for continuous pump operation.

Hydraulic Fluid

Recommendations for hydraulic fluid type, viscosity, temperature, and contamination control.

Operating Environment

Defines acceptable ambient temperature and humidity ranges for pump operation and warns against explosive atmospheres.

Precautions for Operation

Cleaning the Interior of the Tank

Procedure for cleaning the tank before introducing hydraulic fluid.

Introducing the Hydraulic Fluid

Guidelines for filling the pump and managing potential air bubbles during fluid introduction.

Rechecking the Direction of Rotation

Instruction to verify that the motor rotation matches the pump rotation direction.

Pump Start-up

Detailed steps for safe pump start-up, including bleeding air and inching operations.

Trial Run

Procedure for conducting a trial run after start-up, focusing on gradual pressure increase and noise checks.

Maintenance and Inspection Procedures

Cleaning the Suction Filter

Guidance on inspecting and cleaning the suction filter based on operational sound changes.

Control of Hydraulic Fluid

Procedures for analyzing hydraulic fluid for contamination, viscosity, deterioration, and moisture content.

Control of Fluid Temperature

Importance of maintaining hydraulic fluid temperature within specified ranges for viscosity control.

Faults and Corrective Actions