HMP-0567E Rev.7 (16/19)
In general, a filter inspection should be conducted every one to three months.
If a suction filter with a clogging indicator is used, be sure to clean or replace the filter element
within the period in which the indicator is yellow.
Startup after a filter inspection should be performed in accordance with the instructions given in
Section 4.4.
2) Control of hydraulic fluid
Deterioration/contamination of hydraulic fluid occurs due to accumulation of dirt which has passed
through the filter, sludge produced from deteriorated hydraulic fluid, and entry of external water
into the hydraulic circuit, etc.
Contamination of the hydraulic fluid varies depending on the hydraulic system and/or the
surrounding environment, but it is recommended to inspect during the period shown in Table-5.3.1.
3) Control of fluid temperature
It is necessary to control the hydraulic fluid temperature (in the tank) such that the hydraulic fluid
viscosity is within the specified range.
Care needs to be taken if the atmospheric temperature is high, since a rapid increase in hydraulic
fluid temperature may occur due to deteriorated performance of the cooling tower.
Table-5.3.1: Items for Inspection, Intervals between Inspection, and Acceptance Criteria