HMP-0567E Rev.7 (9/19)
b) It is recommended to machine the coupling hole such that the respective dimensions shown
in Table-3.3.1 are within the corresponding tolerances stated in the same table.
c) Do not strike the coupling with a hammer or similar tool in order to attach the coupling to the
pump shaft.
d) Before performing alignment, attach a dial gauge to the coupling, as shown in Figure-3.3.1.
Perform alignment by rotating the coupling.
: ENSURE THAT THE MISALIGNMENT BETWEEN THE SHAFTS IS 0.05 MM OR
LESS AND THAT THE ANGULAR DIFFERENCE BETWEEN THEM IS 1° OR LESS.
e) Certain operations, such as attaching a pipe or transporting/installing the unit, may cause
the misalignment to increase. After performing such operations, be sure to recheck the
misalignment.
Figure-3.3.1: Tolerance of Misalignment
Table-3.3.1: Recommended Coupling Dimensions