10
3) How to Verify Cabinet Temperature
To enter this mode, press [MODE / SET] and [UP or DOWN] until [th] is displayed.
Then press [MODE / SET], and you will see current T-sensor temperature after [t-]
is displayed, current D-sensor temperature after [d-] is displayed, and current P-
sensor temperature after [P-] is displayed. These values will be shown for each 1
second in sequence.
Press [VERIFY] button to return to display cabinet temperature.
4) How to run Turbo Freeze (applies to freezer models only)
To enter this mode, press [MODE / SET] and [UP or DOWN] until [tb] is displayed.
Then press [MODE / SET] for 2 seconds to start turbo freeze.
Once the Turbo Freeze mode is chosen, the compressor will start running
continuously for 2 hours.
5) How to stop Turbo Freeze (applies to freezer models only)
During turbo freeze, press [MODE / SET] for 2 seconds to stop turbo freeze.
The [tb] will flash 5times and then return to normal display mode.
6) How to set Defrost Frequency.
To enter this mode, press [MODE / SET] and [UP or DOWN] until [dt] is displayed
Then press [MODE / SET] to see current defrost frequency.
To change the defrost frequency, press [UP or DOWN] until the desired value is
displayed.
At the end of the sequence, press [MODE / SET] to set the value.
To display the cabinet temperature again, press [UP or DOWN] until [th] is
displayed and then press [VERIFY].
The unit is preset at the factory to defrost every 12hours. (2 defrosts per day).
The defrost frequency can be changed from 4hours to 12hours with a two hour
interval.
During defrosting, [dF] is displayed instead of the cabinet temperature.
7) How to run Force Defrost For service technician Only!
To enter this mode, press [MODE / SET] and [UP or DOWN] until [dF] is displayed.
Then press [MANUAL DF] for 2 seconds to start forced defrost.
8) How to stop Force Defrost For service technician Only!
During forced defrost, press [MANUAL DF] for 2 seconds to stop forced defrost.
The [dF] will flash 5 times and then return to normal display mode.