EasyManua.ls Logo

Summit Accucold ARG23ML - Control Mode

Summit Accucold ARG23ML
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
dF
SE
Hi
Lo
HL
3. CONTROL MODE
1) How to set Cabinet Temperature
To enter this mode, press [MODE / SET] and [UP or DOWN] until [St] is displayed.
Then press [MODE / SET] to see current temperature set point.
To change the set point, press [UP or DOWN] until the desired temperature is
displayed.
At the end of the sequence, press [MODE / SET] to set the temperature.
To display the cabinet temperature again, press [UP or DOWN] until [th] is
displayed and then press [VERIFY]
The temperature set point is the value for the average cabinet.
Temperature is adjustable within certain ranges. (See chart on page 15.)
See chart on page 15 for default temperature set points.
2) How to set Temperature Differential For service technician Only!
To enter this mode, press [MODE / SET] and [UP or DOWN] until [di] is displayed.
Then press [MODE / SET] to see current temperature differential.
To change the set point, press [UP or DOWN] until the desired value is displayed.
At the end of the sequence, press [MODE / SET] to set the value.
To display the cabinet temperature again, press [UP or DOWN] until [th] is
displayed and then press [VERIFY].
The default temperature differential set point is 4°C and the valid setting range is
from 2°C to 10°C.
Compressor ON/OFF: temperature set point ± (temperature differential/2)