Best Practices for the Sun StorEdge 3510 and 3511 FC Arrays 25
3. Configure cache optimization. If you are configuring a Sun StorEdge 3511 SATA
array, confirm that cache optimization is sequential.
4. Create one Logical Drive for each server and configure spare disks.
5. Map Logical Drive 0 to controller channel 0.
6. Map Logical Drive 1 (if created) to controller channel 5.
7. Map Logical Drive 2 (if created) to controller channel 1.
8. Map Logical Drive 3 (if created) to controller channel 4.
9. Connect the first server to controller port FC0.
10. Connect the second server (if needed) to controller port FC5.
11. Connect the third server (if needed) to controller port FC1.
12. Connect the fourth server (if needed) to controller port FC4.
13. After completing the configuration, save the configuration using “Save nvram to
disks” menu option in the firmware application and the “save configuration”
command in Sun StorEdge Configuration Service.