EasyManua.ls Logo

sunair RT-9000B - METER FUNCTIONS

sunair RT-9000B
331 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document No. 8128000560
Software Revision – N1B (07 Oct 04)
7-37
RT-9000 B
When the Coupler BITE test routine finishes, one of the following messages will appear in the Operational
Display. The following summarizes these messages and their meaning.
‘SELECT BITE TYPE’. This message means the Antenna Coupler successfully tuned all three (3) test
frequencies.
‘NO TUNE AT XX XX MHZ’. This message means the Antenna Coupler tuned all test frequencies
successfully prior to the one currently indicated as “No Tune”. In this case, XX XX indicates the
specific test frequency. The decimal point is not displayed.
If a “No Tune” message appears, proceed to Section V of this manual AND the Antenna Coupler manual for
fault isolation and repair procedures.
After this test is completed, the User may do the following:
Repeat the Coupler BITE test. Depressing the ‘CU-BITE’ key again at 4 as shown in Figure 7.3.3.2
will cause the Coupler BITE test routine to repeat.
Repeat the Transmit BITE or Receive BITE tests, as previously covered.
Exit BITE mode. Depressing the ‘END’ key at 3 will return to the main menu and resume normal
operation.
7.3.3.2 METER FUNCTIONS
Several metering functions are available for both Receive-state and Transmit-state conditions. These Meter
choices appear in the Operational Display at 1 as shown in Figure 7.3.3.3.
The available Meter functions are as follows:
RECEIVE:
‘LINE’ - 600-Ohm Line Audio Output
‘S MTR’ - Signal Strength Meter (shown in Figure 7.3.3.3)
TRANSMIT:
‘LINE’ - 600 Ohm Line Audio Input
‘ALC’ - Automatic Level Control voltage
‘FWD’ - Forward RF Power Output
‘RFLD’ - Reflected RF Power