3. Vacuum error: suction motor overcurrent; please check the dirty water suction mechanism
and the floor surface.
Advanced Features
1. Timer Reset
The floor scrubber keeps track of the time when the dirty water suction, brush motor, or
water valve motors are in operation. After accumulating 9999 minutes of operation, you can
reset the timer by simultaneously pressing and holding the "Suction" and "Brush" buttons for
3 seconds.
2. Setting Battery Threshold Voltage
The floor scrubber supports lead-acid and lithium-ion batteries, with a default threshold
voltage of 21.6V for lead-acid batteries and 23.5V for lithium-ion batteries. After turning on
the machine, you can switch the battery threshold voltage by pressing and holding the
"Water" and "Brush" buttons together for 3 seconds.