MAXEON SOLAR TECHNOLOGIES, LTD.
537620 Rev.I
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice. 12
TOP CLAMPS
GEN 5.2 FRAME PROFILE
SunPower Maxeon 6 AC Residenal Solar Panel
(SPR-MAX6-XXX-BLK-E4-AC, SPR-MAX6-XXX-E4-AC)
SIDE FRAME PROFILE
BOLTS
1100mm Holes
+9000/-6000
+6000/-4000
1100mm Holes
Long Side Mounng,
Point Supported
+5400/-5400
+3600/-3600
END FRAME PROFILE
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
A - Ground Holes (4X Ø 4.2mm)
B - Mounng Holes (4X Ø 6.8mm )
1872 mm
0
0
1100 mm
Measurement Tolerances are +/-3mm for the Length and Width of the module.
AB
0
271
525
153
729
0
271
525
153
729
356
356
1 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
pares, unless there is a formal authorizaon by Maxeon.
3 Rails must not be under the Microinverter.
4 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
5 Boom flange mounng
6 Range indicates posioning of the clamp and not the rails
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Perpendicular
to Mounng Frame
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
271 - 525
525 - 729
0 - 153
153 - 271
271 - 525
525- 729
0 - 153
153 - 271
271 - 525
525- 729
0 - 356
0 - 356
0 - 356
+3600/-2400
+2400/-2400
+2400/-2400
+1600/-1600
+1600/-1600
+2400/-1600
+2400/-2400
+5400/-3600
+2400/-2400
+2400/-2400
+2400/-2400
+5400/-3600
+2400/-2400
+2400/-2400
+2400/-2550
+5400/-4050
+1600/-1600
+3600/-2400
+1600/-1600
+1600/-1600
+1600/-1600
+3600/-2400
+1600/-1600
+1600/-1600
+1600/-1700
+3600/-2700
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
32 mm
24 mm
40 mm
40 mm
Microinverter
Exclusion Zone
373 mm
269 mm
137 ± 15mm
137 ± 15mm
43 ± 15mm
1032 mm