MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Appendix: Mounting Configurations and Load Ratings
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 150
Design Load
Long Side Mounng,
Rails Perpendincular
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 254
254 - 423
423 - 646
50 - 150
150 - 254
254 - 423
423 - 646
50 - 150
150 - 254
254 - 423
423 - 646
0 - 350
0 - 350
0 - 350
+2700/-2700
+2700/-2700
+2700/-2700
Test Load
+1800/-1800
+1800/-1800
+1800/-1800
+3600/-3600
+5400/-5400
+3600/-3600
+2700/-2700
+3600/-3600
+5400/-5400
+3600/-3600
+2700/-2700
+3600/-3600
+5400/-5400
+3600/-3600
+2700/-2700
+2400/-2400
+3600/-3600
+2400/-2400
+1800/-1800
+2400/-2400
+3600/-3600
+2400/-2400
+1800/-1800
+2400/-2400
+3600/-3600
+2400/-2400
+1800/-1800
TOP CLAMPS
SunPower Maxeon 3 104 cells Commercial Solar Panel
(SPR-MAX3-XXX-COM)
0
0
GEN 4.2 FRAME PROFILE
SIDE FRAME PROFILE
END FRAME PROFILE
A - Ground Holes (4X Ø4.2mm)
B - Slots (4X 5.0mm(W) x 15mm (L))
C - Mounng Holes (20X Ø6.8mm)
24mm
40mm
32mm
40mm
Mounng
Configuraon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1423mm Holes
Design Load
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
1200mm Holes
539mm Holes
Test Load
+5400/-3600
+5400/-3600
+5400/-3600
+8100/-3600
+8100/-3600
+3600/-2400
+3600/-2400
+3600/-2400
+5400/-2400
+5400/-2400
400mm Holes
400mm Holes
BOLTS
1423mm Holes
1200mm Holes
539mm Holes
+2400/-2400
+3600/-3600
+3600/-3600
+2400/-2400
+5400/-3600
+3600/-2400
1046 mm
1058 mm
1200 mm
1520 mm
1690 mm
0
C
254
423
150
646
0
254
423
150
646
350
A
50
50
350
B
400 mm
539 mm
1423 mm
1623 mm
Downward/Upward
(Pa)
Downward/Upward
(Pa)
Downward/Upward
(Pa)
Downward/Upward
(Pa)
4 Rails must not be under the juncon box.
Descripon
Mounng
Configuraon
Descripon
to Mounng Frame
(End Mount)
1 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
5
I
E
C
6
1
7
3
0
C
e
r
t
Te
s
t
e
d
pares, unless there is a formal authorizaon by Maxeon.
Measurement Tolerances are +/-3mm for the Length and Width of the module.
6 Boom flange mounng.
7 Range indicates posioning of the clamp and not the rails.