Configuration of the cable terminal block:
Temperature sensor
measuring signal: Temp
Solar radiation
measuring signal: Solar
Positive supply, 5V: V+
Supply, GND: V-
Using a small screwdriver, press the orange
terminal. The terminal will open.
Insert the cable stripped to a minimum of
11 mm into the respective terminal hole.
Loosen the screwdriver. The cable is fixed
in the connection.
Once again, check that the cable connec-
tion is firmly located.
Seal the unrequired cable glands by
placing a spare piece of cable in the gland
hole and tightening the screw clamp.