Questions and Answers

  • L
    Lisa TylerAug 1, 2025
    What to do if Sunways REVO-II Inverter buzzer beeps continuously and the red LED is on due to overload?
    • J
      joseph30Aug 1, 2025
      If the buzzer beeps continuously and the red LED is on because the Sunways Inverter is overloaded (over 110%) for too long, reduce the connected load by switching off some equipment. Also, if PV input voltage is higher than specification and connected loads is higher than derated output power, this will cause overload. Reduce the number of PV modules in series or the connected load.
  • C
    Casey BurgessAug 5, 2025
    What to do if Sunways REVO-II buzzer beeps continuously and the red LED is on?
    • M
      Margaret BoydAug 5, 2025
      If the buzzer beeps continuously and the red LED is on, it could be due to several reasons: * A fan fault, in which case you should replace the fan. * The internal temperature of the inverter component is over 100°C, check whether the air flow of the unit is blocked or whether the ambient temperature is too high. * The battery voltage is too high, check if the spec and quantity of batteries meet requirements. * The output is short-circuited, check if wiring is connected well and remove abnormal load.
  • M
    Melissa HurleyAug 9, 2025
    Why is my Sunways REVO-II working in battery mode when mains exist?
    • S
      sherri21Aug 9, 2025
      The Sunways Inverter might be working in battery mode even when mains exist because the input protector is tripped. Check if the AC breaker is tripped and the AC wiring is connected well. It can also be caused by insufficient quality of AC power. Check if AC wires are too thin and/or too long. If a generator is used, verify it's working correctly or if the input voltage range setting is correct. You may also need to change the output source priority to Utility first.
  • X
    xgarrettAug 13, 2025
    What to do if Sunways REVO-II buzzer beeps continuously and the red LED is on due to abnormal output?
    • D
      danielletorresAug 14, 2025
      If the buzzer beeps continuously and the red LED is on because of an abnormal output (Inverter voltage below than 190Vac or is higher than 260Vac), reduce the connected load. Also, if PV input voltage is beyond the specification, reduce the number of PV modules in series.
  • C
    Christina McknightAug 18, 2025
    How to fix Sunways REVO-II Inverter that doesn't respond after power on?
    • J
      Jessica AndersonAug 18, 2025
      If the Sunways Inverter doesn't respond after being powered on, the battery voltage might be far too low. In this case, re-charge the battery or replace it. Another cause might be that the internal fuse tripped, in which case you should contact a repair center to replace the fuse.
  • D
    Daniel SpencerAug 22, 2025
    Why does Sunways Inverter shut down automatically during startup?
    • P
      Paula CobbAug 22, 2025
      The Sunways Inverter might be shutting down automatically during startup because the battery voltage is too low. Try re-charging or replacing the battery.
  • C
    calebhouseAug 27, 2025
    What to do if internal relay is switched on and off repeatedly when Sunways Inverter is turned on?
    • S
      Steven HarrisAug 27, 2025
      If the internal relay switches on and off repeatedly when the Sunways Inverter is turned on, it might be because the battery is disconnected. Check if the battery wires are connected well.

Summary

Safety Instructions

Critical Safety and Operation Guidelines

Provides essential safety and operating instructions for the unit.

Installation Guide

Battery Bank Connection

Procedures and precautions for safely connecting the battery bank.

AC Power Connections

Details on connecting AC power, including breaker specs and cable size.

PV Module Array Connections

Details on connecting PV modules, including cable size and torque.

Operation and Display

LCD Settings Configuration

Fault Code Reference

Fault Event Explanations

Lists fault codes and their corresponding events and potential causes.

Warning Indicator Guide

Warning Event Explanations

Lists warning codes and their corresponding events.

Troubleshooting Common Issues

Startup and Power-On Problems

Addresses issues like auto-shutdown and no response after power on.

Operational Faults and Alerts

Solutions for battery mode operation, relay cycling, and buzzer/LED alerts.