L
Lisa TylerAug 1, 2025
What to do if Sunways REVO-II Inverter buzzer beeps continuously and the red LED is on due to overload?
- Jjoseph30Aug 1, 2025
If the buzzer beeps continuously and the red LED is on because the Sunways Inverter is overloaded (over 110%) for too long, reduce the connected load by switching off some equipment. Also, if PV input voltage is higher than specification and connected loads is higher than derated output power, this will cause overload. Reduce the number of PV modules in series or the connected load.