Dirt and water in the air supply are major causes
of pneumatic tool wear. Use a lter/oiler for better
performance and longer tool life. Ensure the lter
ow capacity is sufcient for the tool’s air volume
use.
Wipe tool clean and inspect for wear or damage.
Use non-amable cleaning solutions to wipe
exterior of tool only if necessary. Do Not Soak
tool with cleaning solutions. Such solutions can
damage internal parts.
Inspect trigger and safety mechanism to assure
system is complete and functional: no loose or
missing parts, no binding or sticking parts.
Keep all screws tight. Loose screws can cause
personal injury or damage the tool.
TROUBLESHOOTING
WARNING: Stop using the tool immediately if any
of the following problems occur. Serious personal
injury may result. Any repairs or replacements
must be done by qualied personnel or by an
authorized service centre only.
CAUTION:
=Disconnect the tool from air supply before
performing any service procedure.
=When inserting new or re-installing O-rings, make
sure they are clean and lubricated with an O-ring
lubricant.
MAINTENANCE
PROBLEM CAUSE SOLUTION
Air leaking in cylinder cap Loose screws in poppet
actuator (FCN50-14)
Tighten the screws and
re-check
Gasket (FCN50-17) is
cracked or worn
Replace gasket
Tool lacks power, slow to
cycle. Poor shooting and
returning performance
Tool is too dry
Add drops of lubricant as
advised
Air pressure is too low Check air supply equipment
Exhaust is blocked Clean exhaust channel