P/N 127055-01 Rev. E 10/2015
REPORT NO. 10-078
PFS
®
USC
P127055-01
Installation and Operation Instructions
Superior
®
Residential and Outdoor Wood-Burning
Fireplace
Models:
WRE3042WS
WRE3042WH
WRE3042RS
WRE3042RH
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec lappareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
This wood burning fireplace complies with UL127
CAN/ULC-S610-M87 standard as a FACTORY
BUILT FIREPLACE.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to
ANS Z21.60, Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard.
An INNOVATIVE HEARTH PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Ac-
cessories, page 19).
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a permit.
POUR LE CANADA: Lautorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant linstallation an de déterminer la
nécessité dobtenir un permis.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace
system. Please read and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of
the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the
warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIREPLACE IN A SQUARE
AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
Question and Answer IconNeed help?

Do you have a question about the Superior WRE3042WS and is the answer not in the manual?

Summary

Save This Book

Safety Information

For Your Safety

Essential safety precautions for using the fireplace safely.

Specifications

Fireplace Installation

Selecting Location

Guidelines for choosing the optimal and safest placement for the fireplace.

Minimum Clearance to Combustibles

Specifies required distances from combustible materials for safe installation.

Framing Procedures

Instructions for framing the fireplace opening and securing the unit.

Drain Pan Requirements

Requirement for a drain pan in outdoor installations for proper drainage.

Hearth Extension

Specifications and requirements for building a hearth extension for floor protection.

Mantel Clearances

Guidelines for installing mantels and clearances to combustible materials.

Venting Installation

Optional Outside Air Kit

Instructions for installing an optional outside air kit for combustion.

Chimney Pipe Information

Information on chimney pipe sections, lineal gain, and labeling requirements.

Double Wall Chimney Assembly

Steps for assembling and installing double wall chimney sections securely.

Using Elbow Offsets

Guidance on using offset elbows for routing chimney systems and related measurements.

Firestop Spacers

Requirement and placement of firestop spacers where chimney penetrates floors.

Firestop Spacers with Attic Space

Details on firestop spacer installation when a ceiling is present above.

Penetrating the Roof

Procedures for cutting roof openings and ensuring proper chimney height and clearance.

Roof Flashing Installation

Instructions for installing roof flashing to ensure a watertight seal.

Storm Collar Installation

How to install a storm collar for sealing the chimney pipe against weather.

Terminations and Spark Arrestor

Approved termination types and spark arrestor requirements for the chimney system.

Chase Installations

Guidelines for installations within a chase, including spacing of multiple terminations.

10 Foot Rule for Termination

Requirements for chimney termination height relative to the roof and surrounding structures.

Finishing the Fireplace Surround

How to finish the fireplace surround with combustible and non-combustible materials.

Optional Gas Line Installation

Gas Line Hook-up and Testing

Instructions for connecting gas lines and testing for leaks.

Operation and Maintenance

Glass Doors Operation

Proper operation and maintenance of glass doors for safe and efficient fireplace use.

Damper and Air Kit Handle Operation

How to operate the outside air kit and damper handles for fireplace control.

Access Cover Plate Location

Instructions for ensuring access cover plates are correctly positioned before use.

Parts List

Accessories

Bi-Fold Glass Doors

Available bi-fold glass door options with finishes.

Double Wall Pipe Sections

Various lengths of double wall pipe sections for chimney assembly.

30 Degree Offset and Return

Offset and return elbow options for routing the chimney system.

Outside Air Kit for Floor Installation

Complete outside air kit for floor installations.

Outside Air Kit for Sidewall Installation

Outside air kit components for sidewall installations.

Storm Collars

Storm collar part numbers for sealing chimney pipe.

Firestop Spacers

Firestop spacer for maintaining clearances.

Roof Flashing Options

Roof flashing options for different roof pitches.

Anti-Draft Shield

Anti-draft shield for round top terminations.

Mesh Round Top Terminations

Round top terminations with mesh screen.

Mesh Round Top Terminations with Slip Section

Round top terminations with slip section and mesh.

Round Top Terminations with Louvers

Round top terminations with louvered screen.

Round Top Terminations with Louvers & Slip Section

Round top terminations with slip section and louvers.

Square Top Terminations with Louvers

Square top terminations with louvers.

Square Top Terminations with Louvers & Slip Section

Square top terminations with louvers and slip section.

Mesh Square Top Terminations

Square top terminations with mesh.

Mesh Square Top Terminations with Slip Section

Square top terminations with mesh and slip section.

Stainless Steel Hood

Stainless steel hood required for vent-free gas logs.

Drain Pan

Drain pan accessory.

Firestop Thimbles

Firestop thimbles for penetrating joists or offsetting.

Important Notice

The Warranty

Coverage Commencement Date

When warranty coverage begins for the fireplace product.

Exclusions and Limitations

Details on what is not covered by the warranty and its limitations.

Limitation on Liability

The extent of the manufacturer's liability for product defects or failures.

Investigation of Warranty Claims

IHP's right to investigate warranty claims and the process.

How to Register a Warranty Claim

Steps for a customer to follow when filing a warranty claim.

Warranty Summary

Summary

Save This Book

Safety Information

For Your Safety

Essential safety precautions for using the fireplace safely.

Specifications

Fireplace Installation

Selecting Location

Guidelines for choosing the optimal and safest placement for the fireplace.

Minimum Clearance to Combustibles

Specifies required distances from combustible materials for safe installation.

Framing Procedures

Instructions for framing the fireplace opening and securing the unit.

Drain Pan Requirements

Requirement for a drain pan in outdoor installations for proper drainage.

Hearth Extension

Specifications and requirements for building a hearth extension for floor protection.

Mantel Clearances

Guidelines for installing mantels and clearances to combustible materials.

Venting Installation

Optional Outside Air Kit

Instructions for installing an optional outside air kit for combustion.

Chimney Pipe Information

Information on chimney pipe sections, lineal gain, and labeling requirements.

Double Wall Chimney Assembly

Steps for assembling and installing double wall chimney sections securely.

Using Elbow Offsets

Guidance on using offset elbows for routing chimney systems and related measurements.

Firestop Spacers

Requirement and placement of firestop spacers where chimney penetrates floors.

Firestop Spacers with Attic Space

Details on firestop spacer installation when a ceiling is present above.

Penetrating the Roof

Procedures for cutting roof openings and ensuring proper chimney height and clearance.

Roof Flashing Installation

Instructions for installing roof flashing to ensure a watertight seal.

Storm Collar Installation

How to install a storm collar for sealing the chimney pipe against weather.

Terminations and Spark Arrestor

Approved termination types and spark arrestor requirements for the chimney system.

Chase Installations

Guidelines for installations within a chase, including spacing of multiple terminations.

10 Foot Rule for Termination

Requirements for chimney termination height relative to the roof and surrounding structures.

Finishing the Fireplace Surround

How to finish the fireplace surround with combustible and non-combustible materials.

Optional Gas Line Installation

Gas Line Hook-up and Testing

Instructions for connecting gas lines and testing for leaks.

Operation and Maintenance

Glass Doors Operation

Proper operation and maintenance of glass doors for safe and efficient fireplace use.

Damper and Air Kit Handle Operation

How to operate the outside air kit and damper handles for fireplace control.

Access Cover Plate Location

Instructions for ensuring access cover plates are correctly positioned before use.

Parts List

Accessories

Bi-Fold Glass Doors

Available bi-fold glass door options with finishes.

Double Wall Pipe Sections

Various lengths of double wall pipe sections for chimney assembly.

30 Degree Offset and Return

Offset and return elbow options for routing the chimney system.

Outside Air Kit for Floor Installation

Complete outside air kit for floor installations.

Outside Air Kit for Sidewall Installation

Outside air kit components for sidewall installations.

Storm Collars

Storm collar part numbers for sealing chimney pipe.

Firestop Spacers

Firestop spacer for maintaining clearances.

Roof Flashing Options

Roof flashing options for different roof pitches.

Anti-Draft Shield

Anti-draft shield for round top terminations.

Mesh Round Top Terminations

Round top terminations with mesh screen.

Mesh Round Top Terminations with Slip Section

Round top terminations with slip section and mesh.

Round Top Terminations with Louvers

Round top terminations with louvered screen.

Round Top Terminations with Louvers & Slip Section

Round top terminations with slip section and louvers.

Square Top Terminations with Louvers

Square top terminations with louvers.

Square Top Terminations with Louvers & Slip Section

Square top terminations with louvers and slip section.

Mesh Square Top Terminations

Square top terminations with mesh.

Mesh Square Top Terminations with Slip Section

Square top terminations with mesh and slip section.

Stainless Steel Hood

Stainless steel hood required for vent-free gas logs.

Drain Pan

Drain pan accessory.

Firestop Thimbles

Firestop thimbles for penetrating joists or offsetting.

Important Notice

The Warranty

Coverage Commencement Date

When warranty coverage begins for the fireplace product.

Exclusions and Limitations

Details on what is not covered by the warranty and its limitations.

Limitation on Liability

The extent of the manufacturer's liability for product defects or failures.

Investigation of Warranty Claims

IHP's right to investigate warranty claims and the process.

How to Register a Warranty Claim

Steps for a customer to follow when filing a warranty claim.

Warranty Summary

Superior WRE3042WS Specifications

General IconGeneral
ModelWRE3042WS
TypeElectric Fireplace
Fuel TypeElectric
Voltage120V
Power Consumption1500W
ColorWhite
Remote ControlYes
ThermostatYes
TimerYes
Fireplace TypeWall Mounted