26
9 Specifications
Operational Voltage Range: 90 to 150 Volts AC
Current rating: 20 Amps
Power Rating: 2,400 Watts
Maximum Load Inrush Energy: 1400 Joules total during power-up
Surge Protection Rating: Grade A (1,000 surges of 6,000 Volts, 3,000 Amps, no
degradation)
Class 1 (SVR is less than 330 Volts for 6,000 Volt, 3,000
Amp surge)
Mode 1 (No ground contamination)
Limiters: Series surge reactor current limiter, cascaded auto-
tracking dual polarity voltage limiters, dual pulse
inverters
Clamping Voltage Onset: 172 Volts nominal, 2 volts above peak line voltage
EMI/RFI Filter Response: With 50 Ohm source and load; -3dB @ 5KHz, -26dB @
100KHz, -38 dB @ 300KHz, -50dB @ 5MHz, -50dB @
30MHz
Let-Through Slew Rate: 28V/us within the AC power wave envelope, less than
10V/us outside the power wave envelope
Maximum Applied Surge Voltage: 6,000 Volts (1.2 x 50 us)
Maximum Applied Surge Current: Unlimited due to current limiting (8 x 20 us)
Maximum Applied Surge Energy: Unlimited due to current limiting (8 x 20 us)
Surge Endurance: As per IEEE C62.41-1991 Category B3; 2KV >100,000;
4KV >10,000; 6KV >1,000 (NRTL Verified)
Number of Outlets: 14
Number of Banks: 3
Delay Time per Bank: 0 to 40 seconds in 1 second increments
Remote Control Voltage: 5 to 30 Volts dc
Remote Control Current Draw: 4 mA maximum
Contact Closure Max. Resistance: 100 Ohms
Auxiliary Relay Contact Rating: 30 Volts dc at 1 Amp
12 Volt Output Max. Current: 40 mA
Voltmeter Accuracy: +/- 2%
0701B