Sutron Accububble
Self Contained Bubbler System
Model 5600-0131-1
Models 5600-0131-3,-4,-5
Models 56-0131-50-1,-2
OPERATIONS &
MAINTENANCE MANUAL
Part No. 8800-1102
Revision - H
Sutron Corporation
21300 Ridgetop Circle
Sterling, Virginia 20166
TEL: (703) 406-2800
http://www.sutron.com/

Table of Contents

Questions and Answers:

Sutron Accububble 5600-0131-3 Specifications

General IconGeneral
BrandSutron
ModelAccububble 5600-0131-3
CategoryMeasuring Instruments
LanguageEnglish

Summary

Sutron Accububble Operations & Maintenance Manual

Initial Setup Guide

Setup and Operation

Making a Measurement

Non-Concurrent Measurement (M Command)

Describes how to use the basic 'M' command for measurements.

Retrieving Measured Data (aD0! Command)

Details how to retrieve data after a measurement using the 'aD0!' command.

Concurrent Measurement (C Command)

Explains the 'C' command for concurrent measurements.

Non-Concurrent Measurement with CRC-16 (MC Command)

Describes using 'MC' command with CRC-16 for data integrity.

Concurrent Measurement with CRC-16 (CC Command)

Explains using 'CC' command with CRC-16 for concurrent measurements.

Changing Units and Calibration

Field Calibration using XE and XS Commands

Procedures for adjusting offset and performing self-calibration.

Configuring Outputs

Configuring Quadrature Output Parameters

Configures quadrature output parameters like scale, threshold, and step rate.

Configuring Analog Output Range

How to set the 0-5V analog output range using the XAR command.

Purge and Averaging Configuration

Configuring Purge Intervals for Power Consumption

Optimizing purge intervals for power saving using XPP command.

Command Reference: Basic Commands

Default Concurrent Pressure Measurement (C!, aD0!)

Commands for default concurrent pressure measurements.

Command Reference: Concurrent Measurements (C Commands)

Concurrent Pressure Measurement in psi (C1!, aD0!)

Commands for concurrent pressure measurements in psi.

Concurrent Temperature Measurement (C2!, aD0!)

Commands for concurrent temperature measurements.

User Scale, Offset, and Calibration (C3!, aD0!)

Commands to request user scale, offset, and field calibration data.

Quadrature Parameters (C5!, aD0!)

Commands to get quadrature output parameters.

Concurrent Temp & Pressure (C6!, aD0!)

Commands for concurrent temp/pressure measurements (V2.0+).

Factory Calibration Temp & Pressure (C7!, aD0!)

Commands for factory calibration temp/pressure measurements (V2.0+).

Command Reference: CRC-16 Concurrent Measurements (CC Commands)

Default Concurrent Pressure with CRC-16 (CC!, aD0!)

Commands for default concurrent pressure measurements with CRC-16.

Concurrent Pressure in psi with CRC-16 (CC1!, aD0!)

Commands for concurrent pressure measurements in psi with CRC-16.

Concurrent Temperature with CRC-16 (CC2!, aD0!)

Commands for concurrent temperature measurements with CRC-16.

User Scale, Offset, Calibration with CRC-16 (CC3!, aD0!)

Commands for user scale/offset/calib. with CRC-16.

Quadrature Parameters with CRC-16 (CC5!, aD0!)

Commands for quadrature parameters with CRC-16.

Temp & Pressure with CRC-16 (CC6!, aD0!)

Commands for temp/pressure measurements with CRC-16 (V2.0+).

Factory Calibration Temp & Pressure with CRC-16 (CC7!, aD0!)

Commands for factory calibration temp/pressure with CRC-16 (V2.0+).

Command Reference: Non-Concurrent Measurements with CRC-16 (MC Commands)

Default Pressure Measurement with CRC-16 (MC!, aD0!)

Commands for default pressure measurement with CRC-16.

Pressure in psi with CRC-16 (MC1!, aD0!)

Commands for pressure measurement in psi with CRC-16.

Temperature Measurement with CRC-16 (MC2!, aD0!)

Commands for temperature measurement with CRC-16.

User Scale, Offset, Calibration with CRC-16 (MC3!, aD0!)

Commands for user scale/offset/calib. with CRC-16.

Quadrature Parameters with CRC-16 (MC5!, aD0!)

Commands for quadrature parameters with CRC-16.

Temp & Pressure with CRC-16 (MC6!, aD0!)

Commands for temp/pressure measurements with CRC-16 (V2.0+).

Factory Calibration Temp & Pressure with CRC-16 (MC7!, aD0!)

Commands for factory calibration temp/pressure with CRC-16 (V2.0+).

Command Reference: Other Measurements (M Commands)

Sutron AccuBubble Extended Commands

Additional Commands for Quadrature Output Units

Additional Commands for Analog Output Units

Installation

Calibration

Troubleshooting and Maintenance

Troubleshooting Checklist: Data Issues

Common causes and solutions for no data or garbled data.

Troubleshooting Checklist: Erroneous Readings

Causes and fixes for incorrect or unstable readings.