FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Measure the resistance.
(Ohm-meter scale: R x 1000)
NOTE : A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
1 3 5
Measure the resistance.
(Ohm-meter scale: R x 1)
Normal:
Abnormal: ∞ or several Ω
00~5001
RELAY 2, RELAY 3
OF P.C.B.
(Wire leads removed.)
Note: Relay
Relay 1: Fan motor
Turntable motor
Oven lamp
Relay 2: Microwave
Relay 3: Grill
Relay 2
Relay 1
Relay 3
Cooking Start OFF
Normal: Approx.100~200K
Abnormal: ∞ or several Ω
L.V.Transformer of P.C.B
(Refer to schemetic diagram)
Check for P.C.B. connector.
Disconnect the 3 pin
connector from P.C.B.
*
Normal
Abnormal
COMPONENTS TEST PROCEDURE RESULTS