Equipment Details
and smell may be noticed for a short
while. This can be remedied by running
the heater at maximum out-put and
ensuring adequate room ventilation.
6. If the burner makes an unusual noise or if
the flame lifts off, it is likely that the
regulator is faulty and it is essential to
have it checked.
7. Items sensitive to heat (e.g. spray cans)
must not be stored in the installation
area, since excess temperatures may
under certain circumstances be incurred
there.
8. For the gas system only gas pressure
regulators with protection against excess
pressure, such as regulators with safety
valves according to EN 12864, DIN 4811
and VP 306, may be used. We
recommend the Truma DUB vehicle
regulator or in the case of a two cylinder
gas installation that is only accessible
from the outside, the Truma Triomatic
automatic reserve switch-over. The Truma
regulators have been specially designed
for heavy-duty use in caravans, boats and
vehicles. In addition to a safety valve for
countering excess pressure, they also
have a pressure gauge with which you
can check that the installation is fully gas
tight.
Always connect the pressure regulators
to the gas cylinders by hand, taking great
care! For temperatures around 0°C and
below, the regulators should be operated
with a defroster system (Eis-Ex). Inspect
regulator connection hoses regularly for
signs of weakness. For winter operation
only use special frost resistant hoses.
Gas cylinders must always be upright!
TECHNICAL DATA
Determined in accordance with prEN or
Truma test conditions
Type of gas:
Liquid gas (propane/butane)
Operating pressure:
30 or 50 mbar (refer to name plate)
Water contents: 12 Litres
Heating up time to approx. 70°C:
approx 35 min (water heater)
approx 80 min (heater + water heater)
Water pressure: max 2.8 bar
Rated thermal output:
C 3402: 2000/3400 W
C 6002: 2000/4000/6000 W
Gas consumption:
C 3402: 170 - 285 g/h
C 6002: 170 - 490 g/h
Air delivery volume
(free-blowing without hot-air pipe)
C 3402:
with 3 hot-air outlets max. 177 m3/h
with 4 hot-air outlets max. 287 m3/h
C 6002:
with 4 hot-air outlets max. 287 m3/h
Current input at 12 V:
Heater + water heater:
C 3402: 0.2 - 2.4 A
C 6002: 0.2 - 5.6 A
Heating up of water heater: 0.4 A
Stand-by: 0.001 A
Current input of electrical safety/drain
valve at 12 V:
0.035 A
Weight: 17.6 kg (without water contents)
ABG test mark:
C 3402: 00
C 6002: 301
Declaration of conformity:
The Trumatic C has been DVGW-tested and
complies with the EC guideline for gas
appliances (90/396/EEC) as well as the
associated EC guidelines. The following CE
Product Ident. No. is available for EU
countries:
C 3402: CE-0085AS0121
C 6002: CE-0085AS0122
The right to effect technical modifications is
reserved.
62

Other manuals for Swift Kon-tiki

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Swift Kon-tiki and is the answer not in the manual?

Swift Kon-tiki Specifications

General IconGeneral
Vehicle TypeMotorhome
Base VehicleFiat Ducato
Width2.35 m
Fuel Tank90 L
LayoutFixed island bed
Engine Options2.3L Multijet
Power140-180 hp
Transmission OptionsManual, Automatic
Berths4
Seatbelts4
Fresh Water Tank100 L
HeatingTruma Combi
Height2.90 m
Gross Vehicle Weight3500 kg
Solar PanelOptional