Equipment Details
63
Gas operation
No control lamp lights up when the
system is switched on (winter and
summer operation).
The red monitor lamp flashes after the
heating system has been switched on.
About 30 seconds after the heating has
been switched on, the red monitor
lamplights up and remains steady.
Heating switches to Fault mode after an
extended period for operation.
- Device fuse or vehicle fuse defective.
- Warning! Battery voltage is too low
(< 10.5 V)
- Gas cylinder or quick closure valve
in the gas line is closed.
- Air feed interrupted.
- Hot-air outlets blocked.
- Gas pressure regulator iced up.
- Check battery voltage (12V). Check all
electrical plug connections/fuses.
- Charge battery.
- Check gas feed.
- Check cowl for possible coverage. If
being used on boats open the deck cowl.
- Check individual outlet apertures.
- Use de-icing system controller (Eis-Ex).
230 V electrical operation
No control lamp lights up when the
system is switched on.
- No supply voltage. -Check 230 V supply voltage and fuses.
FAULT CAUSE RECTIFICATION
TROUBLE-SHOOTING

Other manuals for Swift Kon-tiki

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Swift Kon-tiki and is the answer not in the manual?

Swift Kon-tiki Specifications

General IconGeneral
Vehicle TypeMotorhome
Base VehicleFiat Ducato
Width2.35 m
Fuel Tank90 L
LayoutFixed island bed
Engine Options2.3L Multijet
Power140-180 hp
Transmission OptionsManual, Automatic
Berths4
Seatbelts4
Fresh Water Tank100 L
HeatingTruma Combi
Height2.90 m
Gross Vehicle Weight3500 kg
Solar PanelOptional

Related product manuals