Time delay:
The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive contact
wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will
trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions
during this delay period do not affect the 3-minute duration of the delay.
3.9 Condensation
The air drawn into the heat pump is strongly cooled by the operation of the heat pump for heating the pool
water, this may cause condensation on the fins of the evaporator. The amount of condensation may be as
much as several liters per hour at high relative humidity. This is sometimes mistakenly regarded as a water
leak. If there is excessive water coming from your heat pump please see your installer.