Release the quick coupling (a) by lifting it off the dosing nozzle (c).
Release the quick coupling (b) by pressing down the dosing nozzle.
Remove the dosing nozzle and insert the selected nozzle.
Fix the dosing nozzle by firmly pressing in the two quick couplings (the quick couplings must engage).
Standard dosing nozzles with nozzle designation and flow rates (measured with water):
ULV spraying process ULV-Plus spraying process LV spraying process
Nozzle number/output Nozzle number/output Nozzle number/output
1 20 l/h 4 50 l/h 7 40 l/h
2 25 l/h 5 70 l/h 8 70 l/h
3 30 l/h 6 90 l/h 9 100 l/h
10 10 l/h
11 15 l/h
12 40 l/h
Additional nozzles with specific spray outputs are available if required (optional accessory).
Control unit / remote control
The control unit is attached to the device and can be detached and used as a remote control (e.g. in the driver's cab).
a Ignition key
b Rotary switch: spray/stop/rinse
c Stop position
d Spraying LED
e Rinsing LED
f LV operation LED
g ULV / ULV-Plus operation LED
h LED signal, spraying tank empty
i Device is ready LED
j Cable for remote control
b
a
c
d
e
f
i
g
h
j
The emergency shutdown (5) must be unlocked.
Set the rotary switch (b) to the stop position.
Set the ignition key (a) to the “1” position.
Start the engine by turning the ignition key to the right or by pressing the start button (7). The ignition key must be in
the “1” position.
When starting the device, the choke (13) must be pulled. The choke can be accessed through an opening in the
hood of the device and must be pushed back immediately after the device starts.
If necessary, the engine can also be started using the manual recoil starter (12). The ignition key must be in the
“1” position and the battery (14) must be connected (even if it is not charged).
The manual recoil starter can be accessed by opening the cover in the device's hood. When starting with the
manual recoil starter, the choke must also be pulled.
To fog, set the rotary switch (b) to the spraying position. The device fogs.
To rinse (after use), set the rotary switch to the rinsing position.
The respective positions are indicated by LEDs.
Device stop
Set the rotary switch (b) to the “Stop” position.
Set the ignition key (a) to the “0” position.
Remove the ignition key.
Operating hours metre
The Fontan Mobilstar M is equipped with an operating hours metre. The hours metre is mounted behind the door (10)
for the rinsing liquid tank (11) below the lamp.
The accumulated operating hours are permanently displayed.
The operating hours metre can be reset to “0” as follows:
Press the S1 button until “05” appears on the display.
After approx. 10 seconds, the display will show the accumulated operating hours again.
Simultaneously press and hold the S1 and S2 buttons for approx. 20 - 30 seconds.
This deletes the accumulated operating hours.
Release the “S1” button and wait for about 10 seconds until “0.0” appears on the display.
Once the device is restarted, the operating hours counter metre is starting again at “0.0”.