High Speed
Power Tools
Anspach Electric Systems. High speed
performance and power in a variety of
applications.
Instructions for Use
0x6.001.507_AD 13.06.14 11:11 Seite Cvr1
Question and Answer IconNeed help?

Do you have a question about the Synthes Anspach and is the answer not in the manual?

Synthes Anspach Specifications

General IconGeneral
BrandSynthes
ModelAnspach
CategoryMedical Equipment
LanguageEnglish

Summary

Introduction to Synthes Anspach Systems

Synthes Anspach Overview

Company overview and product philosophy for high speed performance instruments.

High Speed Electric Systems

Overview of eMax 2, eMax 2 Plus, and e12 electric systems and their features.

eMax 2 and eMax 2 Plus Features

Details on eMax 2 and eMax 2 Plus systems, including torque and speed capabilities.

e12 Small Bone System

Description of the e12 system for low speed, high performance surgical applications.

Indications for Use

Intended Surgical Applications

Specifies the intended use of Synthes Anspach High Speed Electric Systems for bone cutting.

Warnings and Cautions

General Safety Precautions

Essential warnings and cautions for safe operation and prevention of injury or damage.

Technical Specifications

eMax 2/eMax 2 Plus System Specs

Detailed technical data for eMax 2/eMax 2 Plus handpieces, consoles, and foot pedals.

Environmental and EMC Specifications

Operating conditions, humidity, pressure, patent information, and general notes.

Glossary of Symbols

Symbol Definitions

Explanation of symbols used throughout the manual for controls, indicators, and warnings.

eMax 2 and eMax 2 Plus Operating Instructions

Console Features and Connections

Overview of console components, ports, and connections for handpieces and controls.

System Assembly Steps

Step-by-step guide for connecting the power cord, foot controls, and handpieces.

Console Face Panel Operation

Instructions for using the console's touch panel for speed, direction, and irrigation control.

Foot Control Operation

Details on operating the handpiece using available foot control options for speed and direction.

Hand Control Assembly and Operation

Guide for attaching and operating the optional hand control for precise handpiece control.

Optional Irrigation System

Instructions for setting up and operating the irrigation system with the console.

System Shutdown Procedure

Steps for safely disconnecting the power cord and shutting down the system.

Console Indicator Lights

Explanation of console error codes and indicator lights for system status.

e12 Small Bone System Operating Instructions

e12 Hand Control Operation

Instructions for attaching and using the optional hand control with the e12 handpiece.

microSaws Attachment Assembly

Procedure for attaching microSaws and small bone attachments to the e12 handpiece.

e12 Duty Cycle Recommendations

Guidelines for recommended usage times for e12 attachments under various conditions.

Attachments and Dissection Tool Assembly

Standard Attachments Overview

Introduction to standard attachments and dissection tool identification.

Straight Attachment Assembly and Use

Instructions for assembling, using, and disassembling straight attachments.

Contra Angle Attachment Assembly

Guide for assembling and using 45° and 90° contra angle attachments.

Craniotome and Specialty Attachment Assembly

Instructions for assembly and use of craniotome and specialty attachments.

QD Angle Attachment Assembly

Procedure for assembling and using QD angle attachments with dissection tools.

Micro Dissection Attachment Assembly

Instructions for assembling and using the micro dissection attachment.

Minimal Access Attachments and Drivers

Guide for installing minimal access attachments and drivers.

Bearing Sleeve and Dissection Tool Assembly

Instructions for assembling bearing sleeves and dissection tools for drivers.

Care and Maintenance

Inspection and Maintenance

Procedures for inspecting system components for damage and ensuring proper operation.

Attachment Inspection Details

Visual checks for straight, angle, and craniotome attachments, including drive shafts and foot.

Accessory and Console Inspection

Inspection of specialty attachments, foot/hand controls, handpieces, and consoles.

Manual Cleaning Procedures

Step-by-step guide for cleaning attachments, handpieces, consoles, and accessories.

Cleaning Specific Components

Detailed cleaning instructions for specific items like consoles, handpieces, and trays.

Sterilization Guidelines

Recommended sterilization methods and exposure times for Anspach system components.

Troubleshooting Electrical Systems

Handpiece and Console Issues

Solutions for common problems like excessive noise, lack of power, and vibration.

Cutting Burr and Attachment Problems

Troubleshooting for cutting burr issues and hot attachments, including bearing damage.

Troubleshooting Controls

Foot and Hand Control Malfunctions

Diagnosing and resolving issues with inoperative foot and hand controls.

Ordering Information

Anspach Attachments and Systems

List of part numbers for Anspach attachments, electric instrument systems, and accessories.