Service and Maintenance / Single Axis Valve Gate Nozzle 16SVH
7) Remove the isolation nut (1).
8) Lift the complete actuator housing (8) from the guide sleeve (9).
Doc007285.png
Doc007432.png
9) Screw the 2 hexagon socket screws
(18) out of the guide sleeve (9),
heater band and bridge (4).
10) Take off the guide sleeve (9) from the heater band (14).