Master Language is English Hot Runner System Installation Guide SVC-17-0001_EN-Rev11
RESTRICTED: Property of Synventive. - 402 - All rights reserved. Errors and omissions excepted
For limited third party distribution based on need and intended use. © 2019 Synventive Molding Solutions
H O T R U N N E R T E C H N O L O G Y
Hot Runner System Installation Guide
Service and Maintenance / Single Axis Valve Gate Nozzle 16SVH
10.3.2.8 Disassembling the Single Axis Valve Gate Nozzle out of the Mold
NOTICE
The Single Axis Valve Gate Nozzle is located on the fit diameters of the nozzle tip and the lower part of the
cylinder housing in the mold.
Doc007349.png
(1)
(8)
(12)
Isolation nut
Actuator
Nozzle tip
Disassembling the Single Axis Valve Gate Nozzle inclusive of actuator out of the mold
1) Cool down the Single Axis Valve Gate Nozzle and the mold to room temperature.
2) Lift the Single Axis Valve Gate Nozzle inclusive of actuator out of the mold.
NOTICE
If it is not possible to lift the Single Axis Valve Gate Nozzle inclusive of actuator out of the mold, please contact
the Synventive Customer Service or Technical Support.