EN
Master Language is English Hot Runner System Installation Guide SVC-17-0001_EN-Rev11
RESTRICTED: Property of Synventive. - 385 - All rights reserved. Errors and omissions excepted
For limited third party distribution based on need and intended use. © 2019 Synventive Molding Solutions
H O T R U N N E R T E C H N O L O G Y
Hot Runner System Installation Guide
Service and Maintenance / Single Axis Valve Gate Nozzle 16SVH
10.3.2.2 Dismounting the Hydraulic Cylinder Housing and Sealing
1) Remove the socket head cap screw (16).
2) Remove the dasher and grounding cable.
Doc007414.png
Doc007284.png
3) Unlocked the Hexagon socket cap
screws.
4) Remove the parallel pins.
5) Fix the nozzle at the isolation nut (1) in a vice.
6) Loosen the isolation nut (1) at the nozzle tip (12).
Doc007386.png