Agency Listings
MOD400R
Field Sensitivity
Test Module
The MOD400R fulfills the NFPA 72 requirement for
detector sensitivity testing.
Features
• Compatible with all System Sensor direct wire and plug-in smoke
detectors (100, 200, 300, 400, and 500 Series), or System Sensor
DH100, DH200, DH400, and DH500 Series duct smoke detectors,
ionization or photoelectronic
• Fulfills NFPA 72 requirement for field sensitivity testing
• Interfaces with standard DC voltmeter or multimeter
• Low battery diagnostic: when connected to a voltmeter, the
MOD400R monitors its own battery voltage
• Quickly tests sensitivity of detectors without putting system into
alarm
The MOD400R Field Sensitivity Test Module is designed to
check the sensitivity of System Sensor 100, 200, 300, 400, and 500
Series conventional detectors or System Sensor DH100, DH200,
DH400, and DH500 series duct smoke detectors. The test module can
be connected to any DC voltmeter (meter movement of 10K ohms/v
or greater) to obtain a reading which correlates to the detector’s
sensitivity range.
S2522 OX5A4.AY

Other manuals for System Sensor MOD400R

Question and Answer IconNeed help?

Do you have a question about the System Sensor MOD400R and is the answer not in the manual?

System Sensor MOD400R Specifications

General IconGeneral
CategoryTest Equipment
TypeTest Module
CompatibilitySystem Sensor compatible devices
Operating Temperature0 to 49 °C
Humidity Range10% to 93% RH
Weight0.5 lbs
FunctionMonitors and tests 4-wire smoke detectors
Dimensions4.5" x 4.5" x 1.5" (114mm x 114mm x 38mm)

Summary

MOD400 R Field Sensitivity Test Module Overview

Product Introduction

Fulfills NFPA 72 requirements for detector sensitivity testing, ensuring compliance and performance.

Key Features

Compatible with various System Sensor detectors, meets NFPA 72, interfaces with voltmeters, and has low battery diagnostics.

MOD400 R Specifications

Physical and Operating Specifications

Details dimensions, shipping weight, test capability for detector series, and battery life.

Testing and Maintenance

Ease of Maintenance

Discusses NFPA 72 inspection requirements and detector disassembly for cleaning insect screens.

Simple Testing Methods

Explains built-in detector tests and why the MOD400R is needed for NFPA 72 sensitivity verification.

Smoke Detector Maintenance

Related product manuals