TGL/DGL Installation Instructions
General
These instructions are intended as general guidelines. The air conditioner must be installed by trained and authorized personnel.
Use the following size copper tubing for connecting the outdoor and indoor units:
Models TGL/DGL 9, 11 - 3/8" and 1/4". Models TGL/DGL 15, 20, 25 - 1/4" and 1/2". Models TGL 30 - 3/8" and 5/8".
Installation must be performed in accordance with the manufacturers specifications, using only approved tubing, original electrical
cables and accessories.
Standard Accessories
Electrical Requirements
The air conditioner must be directly connected to an
appropriate power source.
Use 16A fuses for all Models TGL/DGL air conditioners.
Use a single-length power cable, without extensions.
When installing a Dual System air-conditioner of DGL
series (a single outdoor unit and two separate indoor units)
both indoor units must be connected to the mains power supply in order for the system to function properly.
Indoor and Outdoor Unit Location
The indoor and outdoor units should be installed as
close to each other as possible. Do not exceed the tubing
lengths and height differences which appear in the accompanying
table above:
Outdoor Unit
Make sure to leave sufficient space around the unit. See Figure 1 for
minimum required distances between the unit and nearby walls.
Install the unit in a location with convenient access for service and
maintenance purposes.
Position the unit to minimize motor noise which reaches the customer
and neighbors.
In heating mode, water can form in the condenser. A drainage hose may
be attached to the unit. Use the adapter shown Figure 1.
For opening service door in models TGL 9-20, keep a minimum distance of
0.27m (10" 62') between the unit and the support's end.
Make sure of installing the unit legs to the support.
Indoor Unit
Make sure to leave sufficient space around the unit. See Figure 2 for minimum
required distances between the unit and the ceiling, floor and surrounding walls.
Locate the unit to ensure free air flow around it.
A 120 cm. power cable is supplied with the unit. We recommend placing the power
outlet near the unit, on its right side.
Avoid installing the unit near a
source of heat, such as direct
sunlight, steam or a flame.
Install the unit in a location
with convenient access to
refrigerant line connections
for service and maintenance
purposes.
0.15m (6
")
min.
0.2m
(8
")
min.
1.8−2.5m
(6'-8'3
")
min.
b
c
a
0.2m
(8
")
min.
Fig. 1
Model Maximum tubing Maximum height
length in meters (ft) difference between unit
in meters (ft)
TGL-9, 11, 15, 20, 25, 30 15 (49') 10 (33')
DGL-9, 11, 15, 20 15 (49') 10 (33')
DGL-11/15 15 (49') 10 (33')
Outdoor Model
Dimensions TGL 9-20 TGL 25-30
mm (") DGL ALL Plastic Model
a 320 (32.3") 265 (45.3")
b 641 (12.6") 540 (13.8")
c 1100 (6.7") 730 (7.9")
Fig. 2
Indoor Model
Dimensions TGL 9-20 TGL 25-30
mm (")
a 185 (32.3") 185 (45.3")
b 260 (12.6") 295 (13.8")
c 815 (6.7") 1080 (7.9")
Drain hose adapter
for
DGL/TGL 9-20
WIRELESS DIGITAL REMOTE CONTROLLER
WIRELESS DIGITAL REMOTE CONTROLLER
WIRELESS DIGITAL REMOTE CONTROLLER
WIRELESS DIGITAL REMOTE CONTROLLER
START
STOP
1 2 3 SLEEP
DAILY
MODE FAN
SWEEP
Drain hose adapter
for
DGL/TGL 25-30
Remote Controller
and Batteries
Remote Controller Rack
Insulation for Fittings
User's Manual
Wall Plugs
Long Screws
Mounting Bracket
Outdoor sensor
connecting cable
Absorption cushions
for DGL and TGL 25-30
Electrical terminal block
6/7 stations according
to the model
0.6m(2')
min.
0.15m(6")
min.
a
c
0.6m(2')
min.
0.15m(6")
min.
0.6m
(2')
m
in
.
b
0.6m(2')
0.15m(6")
min.
min.
min.
min.
min.
b
a
c
0.6m(2')
0.6m(2')
0.15m(6")
TGL 9-20 DGL, TGL 25-30
Insert the
drainage adapter
from the inside of
the outdoor unit
Insert the
drainage adapter
from the outside of
the outdoor unit
TGL - 51302613575
50Hz TAC 505 TAC 506 0600
Question and Answer IconNeed help?

Do you have a question about the Tadiran Telecom TGL-9 and is the answer not in the manual?

Tadiran Telecom TGL-9 Specifications

General IconGeneral
BrandTadiran Telecom
ModelTGL-9
CategoryAir Conditioner
LanguageEnglish

Summary

General Installation Guidelines

Standard Accessories

Lists and illustrates standard accessories included with the air conditioner unit.

Electrical Requirements

Details power supply, fuse, and cabling requirements for safe and proper unit operation.

Indoor and Outdoor Unit Location

Provides guidelines for optimal placement of indoor and outdoor units, considering space and service access.

Installing the Indoor Unit

Refrigerant Line Routing

Describes the possible directions for routing refrigerant lines for the indoor unit.

Mounting Bracket Installation

Step-by-step guide for securely mounting the indoor unit bracket to the wall.

Wall Hole Preparation for Indoor Unit

Instructions for drilling the correct size hole in the wall for refrigerant lines and cables.

Drainage System Setup

Details on connecting and testing the indoor unit's drainage hose for proper water flow.

Indoor Unit Wiring

Procedure for connecting electrical cables and sensor wires to the indoor unit.

Remote Controller Rack Installation

Instructions for mounting the rack for the remote controller on the wall.

Connecting Components and Outdoor Unit Installation

Piping and Display Cable Connections

Guidelines for connecting refrigerant lines and the display cable.

Outdoor Unit Installation

Guidelines for correctly positioning and leveling the outdoor unit on a solid surface.

Outdoor Unit Wiring

Steps for connecting electrical terminals and sensor cables to the outdoor unit.

Connecting Refrigerant Lines

Instructions on using approved tubing and connecting refrigerant lines to the units.

Finalizing Installation and Operation

Flaring and Connecting Refrigerant Lines

Procedure for properly flaring and connecting refrigerant lines using specified tools.

Air Vacuum and Refrigerant Charging

Procedure for evacuating air and charging the system with the correct amount of refrigerant.

Finishing Installation Tasks

Final steps including securing tubing, sealing holes, and connecting power.

Customer Handover and User Manual Explanation

Guidance on explaining unit operation, maintenance, and presenting the user manual.

Related product manuals