POSSIBLE PROBLEMS
Problem
When the indicator is on
and the loadbars are
plugged in, the display
shows a big erratic value
which is positive or
negative.
Solution
Repair the cables.
Problem
When the indicator is on
and the loadbars
connected, the display
does not stay on zero, it
creeps up and down by a
few kilograms.
Cause
The loadbars have been
bolted to the ground and
there are uneven horizontal
forces acting on the
loadbar feet.
Solution
Loosen the foundation
bolts and re-align them.
Cause
Problem with cables, cable
damage.
Tal-Tec
11