Technical Data
Appliance Specification
Unit Specifications
T75
T150
T300
T500
Length
1230mm
1450mm
1970mm
2295mm
Width
914mm
914mm
1170mm
1170mm
Height
1000mm
1700mm
1830mm
1995mm
Weight
535kg
950kg
1388kg
1880kg
Heat Output
25kW/Hr
50kW/Hr
100kW/Hr
150kW/Hr
Flue Diameter
180mm (7”)
180mm (7”)
200mm (8”)
255mm (10”)
Air Volume
750 CFM
1500 CFM
3000 CFM
5000 CFM
Power Consumption
0.22 kW
0.26 kW
0.75 kW
2.24 kW
Power Supply
Single phase
13 Amp
Single phase
13 Amp
Single Phase
16 Amp
3 Phase +
Neutral 20 Amp
Loading Door Size
360x360mm
420x360mm
470x470mm
540x540
Fuel types compatible with hand fed T-Range appliances: -
Wood off cuts
Chipboard
MDF
Softwood
Hardwood
Pallets
Off cuts of fuel must not exceed 20% moisture and with dimensions not exceeding
500mm x 100mm x 200mm. Sawdust must not be burned on the appliance.
Responsibilities of the Operating Company
The operating company is responsible for complying with the Health and Safety
requirements as prescribed by law. In addition to the safety instructions contained in
this manual, local regulations regarding safety, accident prevention and environmental
protection must also be complied with.
The operating company must:
- Carry out a risk assessment to determine additional dangers that arise from the
specific working conditions on the site of operation. Specific instructions based
on your risk assessment must be accessible at any time for the operation of the
appliance
- Periodically check whether instructions compiled continue to comply with
updated health and safety guidelines and alter accordingly.
- Define the responsibilities for operation, maintenance and cleaning of the
appliance and appoint a competent person for each role.
- Provide periodic staff training.
- Provide operators with required personnel protective equipment as required.
- Ensure all staff with any interaction with the appliance have read and
understood this manual.