14
Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.
Perform the service and inspection at the intervals shown in the Maintenance schedule below.
NOTE: Use only genuine Talon parts as poor quality parts may damage the generator.
MAINTENANCEPOWER USAGE
13
WATT LEVELS
Application Watts
Lighting:
Fluorescent Lamp 35
Light Bulb 40-100
Flood Lamp 500
Household Appliances:
Vacuum Cleaner 250-1200
Hot Water Service 2500-3500
Iron 900-1200
Kettle or Jug 1600-2400
Blender 300
Radio 60-200
Radiator 1000-2500
Refrigerator 200-500
Television Set 200-250
Toaster 750-1250
Electric Grill 1250
Electric Frying Pan 1150
Microwave 600-1000
Convection Oven 1500
Exhaust Fan 40
Washing Machine 500-3000
VCR 100
Slow Cooker 200
Freezer 700
Hairdryer 1000-1500
Fan Heater 3000
WATT LEVELS
Application Watts
Power Tools:
Welder 140 amp 4000
9" Angle Grinder 2300
Palm Sander 175
Line Trimmer 350-1000
Jig Saw 400
Bench Grinder 400
Orbital Sander 450
Hedge Trimmer 500
4" Angle Grinder 550
1/3 HP Airless Sprayer 600
13mm Hammer Drill 600
Planer 700
5" Angle Grinder 750
Circular Saw 1000-2000
Router 1000-2000
Belt Sander 1000-2000
Cement Mixer 1320
Chain Saw 10"-16" 1500-2000
Hot Air Gun 1500
Air Compressor 2200
9" Grinder 2000
Pressure Washer 1500-2000
Other:
*Electric Induction 180
Motor ¼ hp
*Electric Induction 375
Motor ½ hp
*Electric Induction 750
Motor 1 hp
*Electric Induction 1500
Motor 2 hp
* Induction motors will require 3-5 times the rated
wattage at start-up.
Note: Always consult the data plate on the tool
for specific electrical information.
POWER USAGE REFERENCE GUIDE MAINTENANCE INSTRUCTIONS
REGULAR SERVICE PERIOD (3) - Performed Each First Every 3 Every 6 Every Year
at every indicated month or operating hour interval, Use Month or Months or Months or or 300Hrs
whichever comes first. 20Hrs(3) 50Hrs(3) 100Hrs(3) (3)
ITEM / PIECE / PARTE
ENGINE OIL Check level o
Change o o
AIR FILTER Check o
Clean o(1)
Replace o
SPARK PLUG Check-Adjust o
Replace o
SPARK ARRESTER Clean o
VALVE CLEARANCE Check-Adjust o(2)
FUEL TANK AND STRAINER Clean o(2)
FUEL LINE Check
(Replace if necessary) Every 2 years (2)
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized Talon generator dealer.
(3) For professional commercial use, log hours of operation to determine proper maintenance intervals.
Exhaust gas contains poisonous carbon monoxide. Shut off the engine before
performing any maintenance. If the engine must be run, make sure the area is well
ventilated.
WARNING
Talon Manual_EG500+EG600W_v3.qxp 23/05/2006 4:26 PM Page 13