INSULIN ON BOARD (IOB)
Units 1.1 u 1:09 hrsTime Remaining
B
10:20 AM
March 15, 2015 235 u
OPTIONS
BOLUS
100%

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Tandem T:Slim and is the answer not in the manual?

Tandem T:Slim Specifications

General IconGeneral
BrandTandem
ModelT:Slim
CategoryMedical Equipment
LanguageEnglish

Summary

Section 1 Welcome

1.2 Important Safety Information

Crucial warnings and cautions for safe pump operation.

1.5 Verification of Proper Functionality

Steps to ensure the t:slim Pump is working correctly before use.

1.7 Warnings and Precautions

Critical safety advice and precautions for using the t:slim System.

Chapter 4 Getting Started

4.1 Charging the t:slim Pump

Instructions and precautions for charging the t:slim Pump battery.

Chapter 5 Infusion Site Care and Loading Cartridge

5.1 Infusion Site Selection and Care

Guidelines and warnings for selecting and caring for infusion sites.

5.3 Filling and Loading a t:slim Cartridge

Step-by-step guide for filling and installing a new insulin cartridge.

5.4 Filling Tubing

Instructions for filling the infusion set tubing with insulin.

5.5 Filling Cannula

Steps for filling the infusion set cannula with insulin.

Chapter 6 Personal Profile

6.3 Programming a New Personal Profile

Step-by-step instructions for programming basal and bolus settings.

Chapter 7 Bolus

7.4 Correction Bolus

How to administer a bolus to correct high blood glucose readings.

Chapter 8 Stop/Resume Insulin

8.1 Stopping Insulin Delivery

How to halt all insulin deliveries, including basal and bolus.

8.2 Resuming Insulin Delivery

Steps to restart insulin delivery after it has been stopped.

Chapter 9 Temporary Basal Rate

9.1 Setting a Temp Rate

How to adjust basal insulin delivery for a specific period.

Chapter 10 Quick Bolus

10.1 Setting Up Quick Bolus

How to configure the Quick Bolus feature for fast insulin delivery.

10.2 Delivering Quick Bolus

Steps to use the Quick Bolus feature for rapid insulin delivery.

Chapter 14 User Settable Alerts and Alarms

14.1 Low Insulin Alert

Alerts when insulin levels in the cartridge are critically low.

14.2 Auto-Off Alarm

Alarm triggered by inactivity, potentially stopping insulin delivery.

Chapter 15 t:slim Pump Alerts

15.1 Low Insulin Alert

Alerts when insulin levels in the cartridge are critically low.

15.2 Low Power Alerts

Alerts indicating critical low battery levels and potential shutdown.

15.9 Max Bolus Alerts

Alerts when a requested bolus exceeds the maximum allowed bolus.

Chapter 16 t:slim Pump Alarms

16.1 Resume Pump Alarm

Alarm indicating insulin delivery has been stopped for an extended period.

16.2 Low Power Alarms

Alarms indicating critical low battery levels and shutdown.

16.3 Empty Cartridge Alarm

Alarm indicating the insulin cartridge is empty and deliveries have stopped.

16.4 Cartridge Error Alarm

Alarm indicating the cartridge is unusable or improperly loaded/filled.

16.5 Cartridge Removal Alarm

Alarm indicating the cartridge has been removed, stopping deliveries.

16.6 Temperature Alarm

Alarm triggered by extreme temperatures affecting pump performance.

16.7 Occlusion Alarms

Alarm indicating insulin delivery is blocked, requiring check of site, tubing, and cartridge.

16.8 Screen On/Quick Bolus Button Alarm

Alarm if the button is stuck or malfunctioning, stopping deliveries.

16.10 Reset Alarm

Alarm indicating a micro-processor reset, stopping all deliveries.

Chapter 17 t:slim Pump Malfunction

17.1 Malfunction

Indicates a critical system error requiring immediate customer support.