BODY COMPOSITION ANALYZER
DC-430MA
Instruction Manual
<Usage Conditions> <Storage Conditions>
Temperature Range : 5˚C to 35˚C
Relative Humidity Range : 30% to 80%
(non-condensing)
Max Altitude : 2,000m ASL
Atomospheric Pressure Range : 86kPa to 106kPa
Temperature Range : -10˚C to 60˚C
Relative Humidity Range : 10% to 90%
(non-condensing)
Atmospheric Pressure Range : 70kPa to 106kPa
To avoid malfunctions, avoid storing the equipment in a place with direct sunlight,
significant temperature changes, a risk of dampness, a large amount of dust or a
risk of vibration or impact, or in the vicinity of flames.
Please read this Instruction Manual carefully and keep it forfuture reference.
REMOTE DISPLAY VERSION COLUMN MOUNTED VERSION
III
Question and Answer IconNeed help?

Do you have a question about the Tanita DC-430MA III and is the answer not in the manual?

Overview

The Tanita DC-430MA Body Composition Analyzer is a medical device designed for comprehensive body composition analysis. It is available in two versions: a remote display version and a column-mounted version. The device is clinically proven to be accurate, reliable, and provides highly repeatable results, making it suitable for use by health, research, and medical professionals worldwide.

Function Description

The analyzer measures weight and impedance, and estimates various body composition parameters using Bioelectrical Impedance Analysis (BIA). These parameters include:

  • Body Mass Index (BMI): A measure of body fat based on height and weight.
  • Total Body Fat Percent and Weight: The proportion and mass of fat in the body.
  • Total Body Water Percent and Weight: The proportion and mass of water in the body.
  • Total Body Muscle Mass: The mass of muscle tissue.
  • Physique Rating: An assessment of body type.
  • Bone Mass: The estimated mass of bone minerals.
  • Visceral Fat Rating: An assessment of fat surrounding internal organs, with a healthy range indicated.
  • Basal Metabolic Rate (BMR): The minimum energy required by the body at rest.
  • Fat Free Mass (FFM): The mass of the body excluding fat.
  • Metabolic Age: An indication of the average age associated with the user's metabolic rate.

The device is indicated for use with healthy children aged 5-17 years old and healthy adults with active, moderately active, to inactive lifestyles. It is designed for simplicity, allowing measurements to be taken in under 30 seconds.

Important Technical Specifications

  • Model Number: DC-430MA
  • Accuracy Grade: MDD: CLASS IIa, NAWI: CLASS III
  • Power Source: AC adapter (CINCON TR30M120, centre plus). Input: 100-240V ~ 0.6-0.4A 47-63Hz. Output: 12V === 2.5A.
  • Electric Current Range: 25VA
  • Measurement System: Dual-frequency 4 electrode
  • Measurement Frequency: 6.25kHz / 50kHz
  • Measurement Current: Up to 90μA
  • Electrode Materials: Stainless steel
  • Measurement Part: Between both feet
  • Impedance Measurement Range: 150.0 to 1,000.0Ω (0.1Ω increments)
  • Impedance Accuracy at First Calibration: ±2%
  • Weight Measurement System: Strain gauge load cell
  • Maximum Capacity: 270kg (including preset tare value)
  • Minimum Graduation: 0.1kg
  • Weight Accuracy at First Calibration: ±0.2kg
  • Display: LCD screen
  • Interface: USB B-type connector (device), RS-232C, SD card
  • Usage Conditions Temperature: 5°C to 35°C
  • Usage Conditions Relative Humidity: 30% to 80% (non-condensing)
  • Maximum Altitude: 2,000m ASL
  • Usage Conditions Atmospheric Pressure: 86kPa to 106kPa
  • Storage Conditions Temperature: -10°C to 60°C
  • Storage Conditions Relative Humidity: 10% to 90% (non-condensing)
  • Storage Conditions Atmospheric Pressure: 70kPa to 106kPa
  • Product Weight: Remote Display Version: 7kg, Column Mounted Version: 13.5kg
  • Product Size: Platform: 360mm x 360mm x 94mm, Height (Column Mounted Version): 1070mm

Input Items:

  • Clothes Weight: 0.0kg to 10.0kg (0.1kg increments)
  • ID No.: 16 digits
  • Gender: Female / Male
  • Body Type: Standard / Athletic (Athletic mode for 18-99 years old)
  • Age: 5 to 99 years
  • Height: 90.0cm to 249.9cm (0.1cm increments)
  • Target Body Fat %: 4% to 55% (1% increments)

Output Items (for 18-99 years old unless specified):

  • Weight: 2.0kg to 270.0kg (0.1kg increments)
  • Fat %: 3.0 to 75.0% (0.1% increments)
  • Fat Mass: 0.1kg increments
  • FFM: 0.1kg increments
  • Muscle Mass: 0.1kg increments
  • BMI: 0.1 increments
  • Bone Mass: 0.1kg increments
  • Metabolic Age: 1y increments
  • Basal Metabolic Rate: 1kcal / 1kJ increments
  • Visceral Fat Rating: 1 to 59 (1 increments)
  • TBW: 0.1kg increments
  • TBW %: 0.1% increments
  • Physique Rating: 1 to 9
  • Bioelectrical Data: Resistance / Reactance

Usage Features

  • Measurement Modes: Supports "Body Composition Mode" (with "Two step flow" or "One step flow" options) and "Scale Mode".
  • User Interface: Features an LCD display and intuitive keys for navigation and input.
  • Printer Integration: Includes a built-in printer for immediate output of measurement results. Paper is loaded by opening the printer cover and inserting a 10cm strip of paper.
  • SD Card Slot: Allows for storage of up to approximately 10,000 measurement results (weight only mode) on a 2GB SD card. Data is saved in a YYYYMMDD format.
  • ID Number Function: Can be set to automatically increment or manually entered.
  • Tare Value (Clothes Weight): Allows for input of clothes weight (0.0 to 10.0kg) to ensure accurate body weight measurement.
  • Body Type Selection: Users can select "Standard" or "Athletic" mode, which adjusts calculations for more reliable results based on activity levels.
  • Personal Information Input: Age (5-99 years) and height (90.0-249.9cm) are entered for accurate analysis.
  • Measurement Conditions: For accurate results, it is recommended to measure after sufficient rest, at least three hours after a meal, and at the same time of day under consistent conditions. Inner thighs should not touch during measurement, and transmitting devices like mobile phones should be avoided.
  • Leveling: The device includes a level gauge to ensure it is placed on a stable, level surface. Adjustable feet allow for precise leveling.
  • Data Output: Measurement results can be output to a PC via USB or RS-232C in CSV format.

Safety Precautions:

  • Warning: Failure to follow instructions may result in death or severe injury.
    • Not for use with subjects with pacemakers or other mechanical implants due to weak electrical current.
    • Do not handle the plug with wet hands.
    • Keep away from flammable gas and oxygen-rich environments.
    • Do not modify the equipment.
    • Do not use a multi-plug adapter.
  • Caution: Failure to follow instructions may result in injury or damage to property.
    • Keep away from water.
    • Avoid use on subjects with metal allergies.
    • Do not jump or lean on the equipment.
    • Do not use near other electromagnetic wave-emitting products.
    • Do not insert fingers into gaps or holes.
    • Do not apply force to the display.
    • Assist persons with disabilities or children under 15 years old during measurement.
    • Use the included AC adapter.
    • Unplug the AC cord when moving the equipment.
    • Tighten adjustable feet when moving.
    • Interpretation of analysis results must be performed by a professional.
    • This equipment is a Class B IT device and CE (EMC) certified; maintain 1.5m distance from sensitive devices.

Maintenance Features

  • Daily Checks:
    • Ensure the unit is on a stable, level surface (firm flooring, not thick carpet).
    • Verify date and time settings.
  • Weekly Visual Inspections:
    • Check the display for damage or contamination.
    • Inspect all cables, cords, and connector ends for damage or contamination.
    • Verify legibility of all safety-related labeling.
    • Check all accessories (electrodes, etc.) for wear or damage.
  • Monthly Visual Inspections:
    • Inspect mounting screws on the stand.
  • Cleaning: Clean the scale platform with an appropriate disinfectant after each use. Do not use corrosive chemicals; use a neutral detergent.
  • Troubleshooting Guide: Provides solutions for common issues such as impedance measurement errors, zeroing errors, unstable weight values, display issues, printer errors (paper out, cover open), and SD card problems (insufficient space, write protection, malfunction).
  • Service: Update settings, replace items, or call for service as necessary based on visual inspections. Do not use damaged units without proper operation checks by qualified personnel.

The Tanita DC-430MA is a robust and reliable body composition analyzer designed for professional use, offering detailed insights into body health with ease of use and comprehensive data management capabilities.