21
Cleaning recycling filter co 1500/1700 (option: co 1400/1600/1800)
Caution:
The recycling system is not to use in areas with high hygienic demand e.g.
Hospitals, Food-processing companies, Kitchens, etc.
The recycling system is recommended for low till middle congested areas only.
t Turn off the machine (main switch).
t Empty the recovery tank (Page 17).
t Remove the tank cover closing.
t Take off the tank cover/dosing cup.
t Remove the recycling filter of the recovery tank.
t Rinse the recycling standpipe of the filter thoroughly.
Caution:
Danger of injury due to sharp objects
Wear cloves to protect your hands from injurys!
t Remove the security filter of the recycling standpipe and
clean it.
t Reassemble both filters to the recycling tube.
Caution:
Clogged filters reduce the flow of the cleaning solution. As a consequence
you may damage the floor coating.