20
Servicing the optional filter
Service, maintenance and care
The machines maintenance is a pre-condition for trouble-free running and an
extended life.
Service intervals
TASKI machines are built to the highest quality standards. This is supported by
internationally recognised quality control procedures. Electrical and mechanical
parts are subject to wear or aging if used for long periods of time.
Service centre
Should you contact us due to a malfunction or for placing an order, please
always state the type, description and the serial number of your machine.
You can find this information on the name plate of your machine, and the
address of your nearest TASKI partner can be found on the last page of this
manual.
Malfunctions
Disposal
When it has reached the end of its operational life, the machine and its
accessories must be disposed of according to the national regulations. Your
TASKI partner can support you with proper disposal upon notification.
Technical data
Caution:
The machine may only be operated with the filter disc fitted!
• Place the ridge of the vacuum lid (2) into the
guide provided on the canister (1), then press
down until you hear the fastener catch click into
place.
Heavily soiled exhaust filter
• Remove the exhaust filter and fit a new one.
Heavily soiled HEPA filter
• Vento 15 only: Remove the HEPA filter and
dispose it in accordance with the national
regulations.
HEPA filters cannot be cleaned!
Caution:
Only TASKI branded spare parts must be used, otherwise
warranties and liabilities will be omitted!
Symbols:
◊ = after use, ◊◊ = every week
Activity ◊ ◊◊ page
Checking/replacing the dust bag
Cleaning/replacing the filter cloth 19
Checking/replacing the filter disc 19
Checking/replacing the exhaust filter 19
Checking/replacing the HEPA filter 19
Clean the machine with a damp cloth
• In order to maintain operational reliability and availability for use, the service
must be carried out after 500 working hours or at least once a year.
Under rough or extreme working conditions and / or insufficient maintenance,
shorter periods are necessary.
Malfunction Possible causes Troubleshooting page
Machine does not
run
ON/OFF switch (ON/OFF)
switched off
• Switch the ON/
OFF switch on
19
No power supply
• Plug the power
supply cord into
the mains socket.
Plug not connected to the
power socket on the
machine
• Plug in
19
Power supply cord defect.
• Replace the
power supply cord
ON/OFF switch defective
• Call for technical
assistance
Motor defect
• Call for technical
assistance
Poor vacuum
performance
Dust bag full (safety valve
has been tripped to
prevent the suction motor
overheating)
• Replace
19
Cloth filter soiled
• Clean or replace
cloth filter
19
Filter disc dirty
• Relace the filter
disc
19
Suction hose or sqeegee
nozzle blocked
• Remove the
blockage
HEPA filter dirty (optional:
only on vento 15)
• Replace
20
Exhaust filter (optional) • Replace 19
Build-up of
odours
Accumulation of moisture
• replace the dust
bag
Machine/model type vento 8 vento 15
Rated voltage 220-240V~ 220-240V~ ac
Frequency 50-60 50-60 Hz
Rated power 900 1000 W
Rated power (max.) - 1150 W
Power supply cord length 10.5 10.5 m
Machine weight 6 8 kg
Dimensions (L x W x H) 42x39x34 42x39x48 cm
Assessed sound level LPA according
to EN 60704-1
61 61 dB(A)
Electrical protection class II II