TERMINAL BOARD CONNECTIONS
For Slider Cross Speed 2 MEC-10
110 V Terminals inside transformer housing.
1 – 2 12V DC supply terminal 1 + terminal 2 –
3 4 12V DC 6Ah dry battery input terminals 3 + terminal 4 - This battery guarantees power to
panel for 24 hours with panel in waiting state or 20 minutes with motor running (app. 30
maneuvers) BATTERY IS OPTIONAL.
5 – 6 12V DC OUTPUT max. 80W to power photocells, etc. Terminal 5 + Terminal 6 –
7 – 8 12V DC motor output max. 50W
9 – 10 used in MEC-20 only.
11 – 14 12V DC 20W output for flashing light. Terminal 11 + Terminal 1
12 14 12V DC 12W indicator light output. It is on from beginning of the opening until the gate is
completely closed. Terminal 12 + Terminal 14 –
13 – 14 12V DC 15W electric lock output. Terminal 13 + Terminal 14 –
15 – 17 Pedestrian push button input.
(normally open)
16 17 OPEN/CLOSE push button (step-by-step). Refer for operation to dip switch 3 & 4.
(normally open)
18 – 17 Stop push button. Stop gate in any direction.
(normally closed)
19 – 17 SAFETY input. Photo cells etc.
(normally closed)
20 – 17 Fixed safety edge input. During opening phase the gate will re-close for about 2 seconds.
During closing phase gate will reopen for about 2 seconds.
(normally closed)
21 to 24 Factory connections for limit switch encoder.
DIP SWITCH ADJUSTMENTS
1. ON when the gate is in operation a series of open/close commands activates the gate in the
following sequence OPEN - STOP - CLOSE - STOP -OPEN - STOP etc.
OFF function is determined by dip switch 3
2. ON photocell operates during open and closing.
OFF photocell operates only when gate is closing.
3. ON open/close push button will reverse gate in both directions.
OFF gate will only reverse in closing phase
4. ON enables automatic closure of gate.
OFF the gate will not close automatically
5 & 6 SLOWING DOWN (100% being total travel time)
OFF OFF 95% normal speed 5% at reduced speed
OFF ON 88% normal speed 12% at reduced speed
ON OFF 63% normal speed 37% at reduced speed
ON ON 50% normal speed 50% at reduced speed