WITHOUT SELF-RECOVERY
F3/F6
Hob temperature sensor Short-circuit fault.
(F3 for 1#,F6 for 2#)
Check the connection or replace
the hob’s temperature sensor.
F4/F7
Hob temperature sensor Open-circuit fault.
(F4 for 1#,F7 for2#)
F5/F8
Ceramic hob temperature probe fault -
invalid (F5 for 1#,F8 for 2#)
F9/FA
IGBT Temperature sensor fault.
Short-circuit/open circuit for 1#
Replace the power supply board.
FC /FD
IGBT Temperature sensor fault.
short-circuit/open circuit for 2#
To avoid damage and risks, do not try to dismantle the hob yourself.