17
Refrig Monitor Displays the present state of the refrigeration
system.
Refrigeration Cycle:
• “Wait” = In short cycle delay or in Bypass mode.
• “Cool” = Initial cooling cycle.
• “On” = Normal refrigeration cycle, compressor on.
• “Off” = Normal refrigeration cycle, compressor off.
Timeout – Number of seconds remaining in refrigeration short cycle delay.
• Door: Door Switch status. * indicates door switch on, door closed.
• Out: Compressor output status. * indicates compressor output is on. Compressor
should be running.
• Back: Refrigeration Feedback Relay status. Used to diagnose refrigeration system.
• OK button closes function and returns to the Service menu.
Weighing Monitor Displays the present state of the
weighing system.
Weighing cycle
• Idle - Waiting for a basket size selection.
• Check - Checking Tare weight
• Dispens - In dispense cycle.
• Pulsing - Nearing target weight
• Drop - Dispensing product into basket
• Empty - Dispense cycle has completed, target weight not met.
• Disable - No load selection has been made.
• “Live weight” is the actual calibrated weight on the accumulator doors.
• Out: Drum motor output (* is present when output is on, numbers just to the right indicate
current is present.)
• “Load size” is the current basket load size selection.
• OK button closes function and returns to the Service menu.
Accum Monitor Displays the present state of the
accumulator doors.
Accum. door position:
• Open - Doors.
• Close - In dispense cycle.
• Out: Accumulator door motor output, * indicates on. Number to right indicates current.
• “Accum door state” is the current door state, “Ajar” or “Closed.”
• Home: * Indicates home position has been reached during cycle.
• OK button closes function and returns to Service menu.
Function Name Description
Refrig. Cycle Door:_ Timeout
Out:_ Back:_
Weighing cycle Live weight
Out:_ Load size
Accum. door position Out:_
Accum door state Home:_