Models RD30/RC25 Operating Procedures
150706
Step 3
Dispenser . Prepare a pail of approved 100 PPM
sanitizing solution (examples: 2- 1/2 gal. [9.5 liters] of
Kay- 5R or 2 gal. [7.6 liters] of Stera- SheenR). USE
W ARM WATER AND FOLLOW THE MANUFACTUR-
ER’S SPECIFICATIONS. Remove the upper rear
cover, and open the hopper cover. Pour the sanitizing
solution into the hopper and allow the solution to flow
into the freezing cylinder .
Figure 28
Step 4
Once the mix float switch is submerged in the
sanitizing solution, brush clean the mix hopper, mix
inlet hole, and mix level float switch.
Figure 29
Step 5
Place the control switch in the W ASH” position. This
will cause the sanitizing solution in the freezing
cylinder to be agitated. Allow the solution to agitate for
five minutes.
Figure 30
Step 6
Place the control switch in the OFF” position. Place an
empty pail beneath the door spout. Open the draw
valve and draw off all of the sanitizing solution. When
the sanitizer stops flowing from the door spout, close
the draw valve.
Figure 31
Step 7
Replace the hopper cover and the upper rear cover.
Figure 32
IMPORTANT! The unit must NOT be placed in AUTO
until all sanitizing solution has been removed from the
freezing cylinder and proper priming procedures have
been completed. Failure to follow this instruction may
result in damage to the freezing cylinder.