5 Operation
5 Operation
The extraction and filter system must only be used for the extraction of the substances described in these instructions.
During operation, the condition of the filters must be checked regularly.
Operating, ambient, storage and
transport conditions
Storage and transport temperature °C -25 to +55 (max. 70 C / 24 h)
Working temperature °C 5 to 40
Max. relative humidity % 80 without condensation
Damaging effects from possible condensation are prevented by special
bypass ventilation.
Use Only indoors, dust content of ambient air must not be too high
Max. height above sea level m 2000
Operation - Extraction level of the system can vary by ±10 %.
- If the system is not constantly supplied with a run signal (Pin7+8) via the
interface, it may switch to standby mode if there is a malfunction. The
system can be switched back easily to “Run” via the front panel.
- If you are using the RS232 interface, an EMC-tested adapter must be used
to ensure correct functioning.
5.1 Control elements
5.2 Operation
Manual operation
The diagram shows the front panel with all of the display elements.
65-236