EasyManua.ls Logo

TCL PDP42U3H - Page 19

TCL PDP42U3H
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Press “3” to enter Page3: TV adjustment menu Press “4” to enter Page4: Geometry
picture geometry adjustment menu
Item DATA Item Default data
BLK-STRC 30 HB00-PAL 13
NOLINER 0 VB00-PAL 77
VGAMMA 32 HB00-NTS 29
LINE 10 VB00-NTS 75
STEEP 63 HPNL-PAL 5
CORING 10 VPNL-PAL 77
COLDELAY 7 HPNL-NTS 21
YDELAY 15
VPNL-NTS 73
AGC 4
FFA 1
FOB 1
VCO 63
LOCK OK
FREQ 471.25
I. Voltage adjustment at V
a
and V
s:
(the required values are labeled on the top right corner
of the panel)
1. Coarse adjustment
1) Unplug the output of the power panel, Apply 220VAC to mains power input.
2) Adjust V
a
Adj until voltage at V
a
reaches the required value(±1V).
3) Adjust V
s
Adj until voltage at V
s
reaches the required value(±1V).
2. Fine adjustment
1) Apply a white signal.
2) Press “M“ button to select picture menu, press / to select CONTRAST and
BRIGHTNESS, press / to change the settings to 100.
3) The set warms up about 15 min, then adjust V
a
and V
s
respectively.
Adjust V
a
Adj until voltage at V
a
reaches the required value (±0.5V).
Adjust V
s
Adj until voltage at V
s
reaches the required value (±0.5V).
II. Adjustment of White balance
i. Adjustment of White balance under RGB mode
1. Receive the 16 Gray-scale pattern,
2. Press “PICTURE” key to select STANDARD mode.
3. Adjustment of Warm temperature( 9300K)
1) Set BCUT-9K3 to 200, BGAIN-93 to 15. Use a color analyzer to measure the black
side of the screen (the scale where the luminance is about 5±1nit). Set the reading of
the color analyzer to x=0.284±0.005, y=0.299±0.005 by adjusting the value of RCUT-
9K3 and GCUT-9K3 repeatedly.
2) Then measure the white side of the screen (the scale where the luminance is
100±5nit). By changing the value of GGAIN-93 and RGAIN-93, set the reading of the
color analyzer to x=0.284±0.005, y=0.299±0.005.
3) Repeat step 1) & 2) until you can get the correct reading for both black and white
sides.
4. Adjustment of Cool temperature (11000K)
1) Set BCUT-11K to 200, BGAIN-11 to15. Use a color analyzer to measure the black side
of the screen (where the luminance is 5±1nit). By changing the value of RCUT-11K
19