1. BATTERY AND CHARGER
- 10 -
In addition, the VTM unit has a function that sets the traveling and lifting speed limit and regenerative
brake operating levels. You can change such settings in the following manner:
Observe the following conditions when changing those settings.
Note 1. When changing those settings on the VTM unit, inform your local TCM dealer of the model
name, chassis serial number of the truck you are going to change those settings, and the user
name of the said truck.
Note 2. Do not change the other settings on the VTM unit.
Mode Factory set level Change
Traveling and lifting speeds
They are increased by increasing the level.
Traveling speed change
No “turtle” mark
Traveling speed: 100%
“turtle” mark
Level 8: 90% of full speed
7: 80% of full speed
6: 70% of full speed
5: 60% of full speed
4: 50% of full speed
3: 40% of full speed
2: 30% of full speed
1: 20% of full speed
Tilt speed
Attachment speed
Accelerator OFF regeneration
Regeneration force obtained while traveling with
accelerator OFF can be enhanced by increasing
the level.
Brake regeneration
Enabled when the brake switch is turned on.
1.5-ton class
2- to 3-ton
class