※Contact TDK-Lambda concerning items not mentioned or items which are not clear.
CC15
CC15CC15
CC15-
--
-xxxxSxx
xxxxSxxxxxxSxx
xxxxSxx-
--
-E , CC30
E , CC30E , CC30
E , CC30-
--
-xxxxSxxx
xxxxSxxxxxxxSxxx
xxxxSxxx-
--
-E Series Instruction Manual
E Series Instruction ManualE Series Instruction Manual
E Series Instruction Manual
1. Standard Connection Method
1. Standard Connection Method1. Standard Connection Method
1. Standard Connection Method
The connection method shown in Figure 1.
DC
Input
Load
+Vin
-Vin
+Vout
-Vout
PO
RC
ALM
Fuse
SW
Fig. 1 Connection Method
When not using the Remote Control function, use it with either the RC terminal open or connected to the Vin terminal.
When not using the Alarm function, use it with the ALM terminal in an open condition.
Use the PO terminal for controling multiple unit operation (series, parallel operation etc.).
For single unit operation, use the PO terminal in an open condition.
The converter is to be operated exclusively on DC input. Use of AC input will cause damage.
2. Block Diagram
2. Block Diagram2. Block Diagram
2. Block Diagram
The block diagram is shown in Figure 2.
  
DRIVE
+Vin
-Vin
RC
Control circuit
Auxiliary power
DRIVE
+Vout
-Vout
OCP
Voltage
detection
OVPLVP
+Vin
-Vin
PO
ALM
+Vout
+Vout
-Vout
Voltage detecyion
(Hysteresis type)
Delay circuit
(20ms50ms)
Fig. 2 Block Diagram
Question and Answer IconNeed help?

Do you have a question about the TDK-Lambda CC30-xxxxSxxx-E Series and is the answer not in the manual?

Summary

Standard Converter Connection Method

Figure 1 Connection Method Details

Describes terminal connections for Remote Control, Alarm, and Parallel/Series operation.

Converter Block Diagram Explanation

Figure 2 Block Diagram Overview

Illustrates the internal components and control logic of the DC/DC converter.

Input and Output Line Connection Guidelines

Recommended Fuse Capacity for Input Lines

Specifies fuse capacity based on converter type and input voltage configuration.

External Capacitor for Input Line Stability

Details when and how to use an external capacitor for input line inductance and stability.

Input Ripple Noise Reduction Circuit

Details connecting an external filter to reduce input ripple noise voltage.

External Circuit for Reverse Polarity Protection

Provides a circuit diagram to prevent damage from reverse input voltage polarity.

External Capacitor for Output Pulse Load Stability

Recommends Cout values for connecting pulse loads to the converter output.

Output Ripple Noise Voltage Measurement Circuit

Describes the recommended circuit and method for measuring output ripple noise.

Terminal Functions, Protection, and Operation Modes

Remote Control (RC Terminal) Operation and Wiring

Explains RC terminal function for output control and provides two connection methods.

Alarm (ALM Terminal) Monitoring and Usage

Details ALM terminal function for abnormality monitoring and its maximum sink current.

Simultaneous Start-Up;Stop (PO Terminal) Synchronization

Explains using the PO terminal to synchronize multiple converter start-up and stop events.

Over-Current and Low-Voltage Protection Features

Describes built-in OCP and LVP, their operation, and recovery from shutdown.

Over-Voltage Protection (OVP) Activation and Recovery

Details OVP activation thresholds, potential exceptions, and recovery procedures.

Converter Operational Sequence Diagram

Illustrates the timing sequence of Vin, Vout, PO, ALM, and RC signals during operation.

Series Operation Configuration Guide

Explains how to connect identical converters in series for increased output voltage, max 2 units.

Parallel Operation Configuration Guide

Explains how to connect identical converters in parallel for increased output current, max 10 units.

Soldering, Cleaning, and Installation Procedures

Soldering Conditions for DIP and SMD Models

Provides specific temperature and time parameters for soldering DIP and SMD converter packages.

Cleaning Fluid and Method Recommendations

Outlines recommended cleaning fluids and methods if post-soldering cleaning is required.

PCB Installation Method and Trace Pattern Prohibitions

Advises on PCB layout during installation to prevent insulation defects by avoiding specific trace patterns.