1. Standard Connection Method
1. Standard Connection Method1. Standard Connection Method
1. Standard Connection Method
The connection method shown in Figure 1.
DC
Input
Load
+Vin
-Vin
+Vout
-Vout
PO
RC
ALM
Fuse
SW
Fig. 1 Connection Method
When not using the Remote Control function, use it with either the RC terminal open or connected to the Vin terminal.
When not using the Alarm function, use it with the ALM terminal in an open condition.
Use the PO terminal for controling multiple unit operation (series, parallel operation etc.).
For single unit operation, use the PO terminal in an open condition.
The converter is to be operated exclusively on DC input. Use of AC input will cause damage.
2. Block Diagram
2. Block Diagram2. Block Diagram
2. Block Diagram
The block diagram is shown in Figure 2.
  
DRIVE
+Vin
-Vin
RC
Control circuit
Auxiliary power
DRIVE
+Vout
-Vout
OCP
Voltage
detection
OVPLVP
+Vin
-Vin
PO
ALM
+Vout
+Vout
-Vout
Voltage detecyion
(Hysteresis type)
Delay circuit
(20ms50ms)
Fig. 2 Block Diagram
Question and Answer IconNeed help?

Do you have a question about the TDK-Lambda CC15-xxxx-Sxx-E Series and is the answer not in the manual?

Summary

Standard Connection Method

Connection Method Details and Terminal Usage

Details on RC, ALM, PO terminal usage and input voltage constraints for standard connection.

Block Diagram Overview

Input; Output Line Connection

Recommended Fuse Capacity for Input Protection

Recommended external fuse capacities for CC15 and CC30 series converters based on type.

Input Side External Capacitor Selection

Guidelines for selecting and connecting external input capacitors based on line length and inductance.

Input Ripple Noise Reduction Techniques

Methods to decrease input ripple noise voltage using external filters, as shown in connection diagrams.

Prevention of Reverse Polarity Connection Damage

External circuit recommendations to prevent damage from reverse polarity input voltage.

Output Side External Capacitor for Pulse Loads

Connecting external capacitors to the output terminals for pulse load applications to ensure stability.

Output Ripple Noise Voltage Measurement Procedure

Procedure for measuring output ripple noise voltage, including probe connection details and avoiding magnetic flux.

Terminal Function, Protection, and Operation Modes

Remote Control (RC Terminal) for Output ON;OFF

Using the RC terminal for output ON/OFF control and recommended connection methods for noise prevention.

Alarm (ALM Terminal) Monitoring of Abnormal States

How to monitor abnormal states using the ALM terminal and its internal circuit, including sink current limits.

Simultaneous Start-Up; Stop (PO Terminal) Synchronization

Synchronizing multiple converter units using the PO terminal for start-up/stop timing, with connection limits.

Over-Current and Low-Voltage Protection (OCP;LVP) Operation

Details on built-in OCP and LVP circuits, their operation, trigger points, and recovery methods.

Over-Voltage Protection (OVP) Circuit Function

Explanation of the built-in OVP circuit, trigger conditions, output shutdown, and recovery.

Converter Operation Sequence Overview

Sequence of operations for input voltage, output voltage, and control terminals (RC, PO, ALM) during start-up and protection events.

Series Operation Configuration and Limitations

Guidelines and connection examples for operating converters in series, including maximum unit limits.

Parallel Operation Configuration and Wiring

Guidelines and connection examples for operating converters in parallel, emphasizing wiring consistency for current balance.

Soldering, Cleaning, and Installation Methods

Soldering Conditions for DIP and SMD Models

Recommended soldering temperatures, times, and reflow process conditions for DIP and SMD package types.

Cleaning Conditions After Soldering

Recommended cleaning fluids, methods, and test conditions when post-soldering cleaning is necessary.

Installation Method: PCB Trace Pattern Prohibitions

Design guidelines for PCB layout, specifying prohibited trace pattern areas to prevent insulation defects.