when the pressure arrived the set pressure value, the heating indicator show the green
light.
4. When the boiler water level is full of water, the full water indicator “F” lights up
and alarms 1 sec.
5. When the machine is short of water during use, the heating automatically stops, the
shortage water indicator “L” lights up and alarms; at the same time start the automatic
water procedure. While the boiler is still under high pressure, it should be released by
gently stepping on the pedal switch. When the boiler pressure displays “0”, the pump
will be started, the heating function restarted after the full water.
6. There are four kinds of steam pressure adjustable from 2 - 5 bar.
7. Touch the power button again in the boot state to shut down and enter the standby
state, but the steam solenoid valve can work normally in the standby state. After
turning off the main power switch at the back of machine, the exhaust fan will
continue to exhaust and cool down for a while. When the internal temperature of the
machine drops, the exhaust fan will automatically stop.