Recording Times
1-12
Recording Times
z Recording to Memory, 8 channels, 64 MB standard memory (when not recording voice memos
z Recording to MO, 8 channels (when not recording voice memos
* This recording time at a 48 kHz sampling frequency is the value when using an MO disk on which nothing is
recorded after formatting.
z Recording to PC card, 8 channels, 1 GB PC card is used (when not recording voice memos
* This recording time at a 48 kHz sampling frequency is the value when using an MO disk on which nothing is
recorded after formatting.
z Media recording time can be calculated as follows (result by approximately times.):
Recording Time (seconds) = (Media Capacity (Bytes) x 0.9) / [(Number of Analog Input Channels + Number of
Tachometer Input Channels) x Sampling Frequency (Hz) x 2 + 8000]
Media Capacity x 0.9: Considering recording overhead of the media and an additional capacity needed for the
header files, multiply 0.9 (90%) for the used capacity for data files.
Refer the tables later for a combination of the Sampling Frequency vs. the number of analog input channels can be
selected in each recording mode.
Number of tachometer input channels: use "2" in 16 bits mode, "2" for 32 bits/1 channel mode, or "4" for 32 bits/2
channels mode. Use "0" instead of 8000 when the memo voice recording turns to OFF.
Sampling frequencyValue in brackets is the recording
bandwidth with tolerances of +/-0.5 dB)
Recording time
96 kHz 40 kHz 40 s
48 kHz 20 kHz 80 s
24 kHz 10 kHz 160 s
12 kHz 5 kHz 320 s
6 kHz 2.5 kHz 640 s approx. 10 min
3 kHz 1.25 kHz 1,280 s approx. 21 min
1.5 kHz 625 Hz 2,560 s approx. 42 min
Sampling frequencyValue in brackets is the recording
bandwidth with tolerances of +/-0.5 dB)
Recording time
48 kHz 20 kHz 1,600 s approx. 26 min *
24 kHz 10 kHz 3,200 s approx. 53 min
12 kHz 5 kHz 6,400 s approx. 106 min
6 kHz 2.5 kHz 12,800 s approx 213 min
3 kHz 1.25 kHz 25,600 s approx. 7 h
1.5 kHz 625 Hz 51,200 s approx. 14 h
Sampling frequencyValue in brackets is the recording
bandwidth with tolerances of +/-0.5 dB)
Recording time
48 kHz 20 kHz 1,230 s approx. 20 min *
24 kHz 10 kHz 2,470 s approx. 41 min
12 kHz 5 kHz 4,940 s approx. 82 min
6 kHz 2.5 kHz 9,890 s approx. 164 min
3 kHz 1.25 kHz 19,790 s approx. 329 m
1.5 kHz 625 Hz 39,360 sec approx. 11 h