E4
incline did not self-test
Check the incline wiring and the plug. Check the AC
wiring of the incline motor. Check the wiring of the
motor. After check, Press the incline button on the
control board, Self-test can be completed then can use
again.
E5
Electricity is too high: When
the treadmill is running, the
controller test there is big
electricity than the standard
electricity +6A, last 3seconds.
The treadmill can’t work and not switch on. Computer
show E5, other places no showing and cause warning
sound 9 times. Stop the treadmill; if it returns to the
normal appearance, it can start again.
CauseThe electricity is too high than the standard,
there is a self-protect. Or there is something stocking
somewhere, so the motor can’t work. Restart the
treadmill. Besides, check if there is noise and burnt
smell when running, and then change the motor. Or
check the controller, if there is burnt smell, change the
controller. Or check the voltage is standard or not, use
the right voltage to test again.
E6
Voltage is not correct
The treadmill can’t work and not switch on. Computer
show E5, other places no showing and cause warning
sound 9 times. Stop the treadmill, if it return to the
normal appearance, it can start again..
Cause: check the voltage is lower than 50% of the
standard voltage. Use the correct voltage to test again.
Check whether there is some smell in the controller,
and then change the controller. Check the wiring of the
motor.
E9
Incline failure
Check the incline motor wiring and the plug. Check the
AC wiring of the incline motor. Check the wiring of the
motor. After check, Press the incline button on the
control board, Self-test can be completed then can use
again.