1
1 - 9
Capacity [minimum~maximum] kW
BTU/h
Air circulation (Hi/Me/Lo) m3/h
Moisture removal (High) Liters/h
Voltage rating V
Available voltage range V
Running amperes* A
Max–Running amperes** A
Power input kW
C.O.P W/W
Max. Starting amperes A
Controls/Thermostat control
Timer
Fan speeds Indoor/Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (Drain connection)
Compressor
Operation sound Indoor - Hi/Me/Lo dB - A
Outdoor - Hi dB - A
Color (Approximate value) Indoor
Outdoor
REFRIGERANT TUBING
Limit of tubing length m (ft.)
Limit of tubing length at shipment m (ft.)
Limit of elevation difference m (ft.)
between the two units
Refrigerant tube Narrow tube mm (in.)
outer diameter Wide tube mm (in.)
Refrigerant amount at shipment kg
DIMENSIONS & WEIGHT
Unit dimensions Height mm (in.)
Width mm (in.)
Depth mm (in.)
Package dimensions Height mm (in.)
Width mm (in.)
Depth mm (in.)
Net weight kg (lb.)
Shipping weight kg (lb.)
Shipping volume
m
3
(cu. Ft)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Cooling:
Rating conditions (*): Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**): Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Heating:
Rating conditions (*): Indoor air temperature 20°C DB, Outdoor air temperature 7°C DB/6°C WB
Full load conditions (**): Indoor air temperature 24°C DB, Outdoor air temperature 24°C DB/15.5°C WB
MODEL No. Indoor Unit MAFP185Rx2
Outdoor Unit GRFP365R
POWER SOURCE 220 - 230 - 240 V/1 phase/50/60 Hz
PERFORMANCE Cooling Heating
1,560/1,320/960 (780/660/480x2)
4.2 (2.1x2)
ELECTRICAL RATINGS
230 240
198 - 264 198 - 264
220 230 240 220
16.8 16.0 15.3 15.6
3.053.283.29
14.9 14.3
3.67 3.673.05 3.04 3.04 3.68
3.29 3.04 3.05
FEATURES
Microprocessor/I.C.thermostat
3 and Automatic control/Variable
ON/OFF 72-hours
Automatic (Remote control)
Washable, easy access
Wired : REM HW Wireless : REM HLAWS
(13A , OD18mm)
Rotary(SANYO)
38/34/30
51/52
Munsell 3.0Y8.6/0.8
Munsell 1Y 8.5/0.5
50 (164)
5~30 (16~98)
Outdoor unit is higher than indoor unit : 30 (98)
Outdoor unit is lower than indoor unit : 15 (49)
6.35 (1/4)
12.7 (1/2)
R410A - 2.8
Indoor unit Outdoor unit
285 (11-7/32) 780 (30-23/32)
995 (39-6/32) 940 (37)
203 (8) 340 (13-3 /8)
347 (13-21/32) 888 (34-31/32)
1,065 (41-30/32) 1015 (39-31/32)
260 (10-8/32) 409 (16-3/32)
0.096 (3.4) 0.369 (13.0)
10.0 [2.2~11.2] 11.2 [2.2~12.5]
34,000 [7,500~38,000] 38,000 [7,500~42,500]
12 (27) 65 (143)
15 (33) 73 (161)
1-1. Unit Specifications
Wall-Mounted Type MAFP185Rx2/ GRFP365R
04-163 Sanyo-1_p1-29 7/28/04 5:43 PM Page 25